Daikin FDXS09DVJU Installation Manual page 6

R410a split series
Hide thumbs Also See for FDXS09DVJU:
Table of Contents

Advertisement

Mount chamber lid
and air filter
(accessory).
For bottom intake, replace the chamber lid and
the protection net in the procedure listed in Fig.
(1)Remove the protection net. (6 locations)
Remove the chamber lid. (7 locations)
(2)Reattach the removed chamber lid in the
orientation shown in Fig.(7 locations)
Reattach the removed protection net in the
orientation shown in Fig. (6 locations)
Refer to Fig.for the direction of the protection
net.
(3)Attach the hanger (right) insulation to the right hanger. (Stored in outlet vent)
(See the below figure for the sticking base line.)
(4)Attach the air filter (accessory) in the manner shown in the diagram.
In case of bottom side
When two indoor units are installed in one room, one of the two wireless remote controllers can be easily
set for another addresses.
PCB in the indoor unit
• Cut the jumper
JA on PCB.
ADDRESS:
JA
JA
EXIST
1
JB
ADDRESS
CUT
2
JC
(1)
Protection net
Air discharge
Main unit
Attach the
Force
filter to the
main unit
while
pushing
Filter
down on the
Force
2 bends.
Wireless remote controller
• Cut the jumper J4.
1
2
3
(2)
Air inlet
Chamber lid
Air discharge
In case of back side
Wireless
remote
controller
J4
ADDRESS
EXIST
1
CUT
2
Chamber lid
Protection net
Air inlet
J4
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fdxs12dvju

Table of Contents