Note For Multi System - Daikin FTKD50JVET Operation Manual

Inverter
Hide thumbs Also See for FTKD50JVET:
Table of Contents

Advertisement

Installation site
■ To install the air conditioner in the
following types of environments, consult
the shop.
● Places with an oily ambient or where
steam or soot occurs.
● Salty environment such as coastal
areas.
● Places where sulfide gas occurs such
as hot springs.
● Places where snow may block the
outdoor unit.
The drain from the outdoor unit must be
discharged to a place of good drainage.
Consider nuisance to your
neighbours from noises
■ For installation, choose a place as
described below.
● A place solid enough to bear the
weight of the unit which does not
amplify the operation noise or vibra-
tion.
● A place from where the air dis-
charged from the outdoor unit or the
operation noise will not annoy your
neighbours.
Electrical work
● For power supply, be sure to use a
separate power circuit dedicated to the
air conditioner.
System relocation
● Relocating the air conditioner requires
specialized knowledge and skills.
Please consult the shop where you
bought the air conditioner if relocation is
necessary for moving or remodeling.
4
Note for Multi
System
● Precedence-room setting
When setting the preference-room during installation, the
indoor unit's operation mode always takes priority.
When the precedence-setting room unit is operated in
POWERFUL mode, there are times that air conditioners
in other rooms will temporarily stop in order to centralize
power to the unit in the room.
Please adjust the precedence-room setting to match your
life style. Moreover, for precedence-room settings, please
consult the service shop where you bought the unit.
∗ Precedence-room setting is applied to only 4MX80,
4MK90.
● COOL/HEAT mode
This mode is used to set the unit to only cool or heat. For
information on using this mode, consult the service shop
where you bought the unit.
∗ COOL/HEAT mode is applied to only 4MX80.
NOTE
<Note for heat pump multi system>
When two or more indoor units have no precedence-
room settings and are set to modes that differ from
each other, the indoor unit which is operated first
activates, while the other indoor unit does not activate
and the OPERATION lamp blinks. (This is not a
malfunction.)
An indoor unit that is not in operation will
automatically start and operate in the mode in which
a previously operated indoor unit was stopped.
However, if the unit in operation provides only COOL
and DRY modes, simultaneous operation is
possible.
● Precautions for outdoor unit connected to
RMX140
• In heating operation, when all indoor units are
stopped, the outdoor unit stops its operation
automatically after 5 minutes. This is a part of
preparation process for the next operation, not a
failure.
• In heating operation, no warm air may come out
temporarily. This is for an oil recovery operation
performed at certain time intervals, not a failure.
• In simultaneous operation at two or more rooms,
when heating operation is performed at one room,
cooling operation cannot be performed at other rooms.
Whichever mode selected first is preferred.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftkd60jvetFtkd71jvetFtxd60jvetFtxd50jvetFtxd71jvet

Table of Contents