3. OPERATION RANGE

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the
air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING
OUTDOOR
TEMPERA-
UNIT
TURE
D
RKS25 · 35 ·
B 21 to 32
50 · 60
RXS25 · 35 ·
W
50 · 60
14 to 23
B
RMXS112 · 140 ·
D
160
B 21 to 32
RMKS112 · 140 ·
160
3MKS58 · 75
W
4MKS90
14 to 23
B
3MXS52 · 68
4MXS80
HEATING
OUTDOOR
INDOOR
UNIT
TEMPERATURE
RXS25 · 35
DB
RXS50 · 60
DB
RMXS112 · 140 ·
160
DB
3MXS52 · 68
4MXS80
DB: Dry bulb temperature (°C)
WB: Wet bulb temperature (°C)
The setting temperature range of the remote con-
°
°
troller is 16
C to 32
C.
The numerical value in a parenthesis shows the
operation range of the model for Australia.
Tips for saving energy
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate
level helps save energy.
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases
the cooling (heating) effect.
Recommended temperature setting
For cooling
For heating
English
INDOOR
OUTDOOR
TEMPERA-
HUMID-
TURE
ITY
80% or
D
–10 to 46
below
B
(–5)
80% or
D
–10 to 46
below
B
OUTDOOR
TEMPERATURE
DB
–14 to 24
10 to 30
WB
–15 to 20
DB
–14 to 24
10 to 30
WB
–15 to 18
DB
–14 to 21
10 to 30
WB
–15 to 15.5
26 to 28 °C
20 to 24 °C

4. INSTALLATION SITE

Regarding places for installation
• Is the air conditioner installed at a well-venti-
lated place where there are no obstacles
around?
• Do not use the air conditioner in the following
places.
a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach
area
c. Where sulfured gas exists such as a hot-spring
resort.
d. Where there are considerable voltage
fluctuations such as a factory or plant
e. Vehicles and vessels
f. Where there is much spray of oil and vapor
such as a cookery, etc.
g. Where there are machines generating
electromagnetic waves.
h. Filled with acid and/or alkaline steam or vapor
• Is a snow protection measure taken?
For details, consult your dealer.
Regarding wiring
• All wiring must be performed by an autho-
rized electrician.
To do wiring, ask your dealer. Never do it by
yourself.
• Make sure that a separate power supply circuit
is provided for this air conditioner and that all
electrical work is carried out by qualified per-
sonnel according to local laws and regulations.
Pay attention to running noises, too
• Are the following places selected?
a. A place that can sufficiently withstand the
weight of the air conditioner with less running
noises and vibrations.
b. A place where the hot wind discharged from
the air outlet of outdoor unit and the running
noises.
• Are you sure that there are no obstacles near
the air outlet of the outdoor unit?
Such obstacles may result in declined perfor-
mance and increased running noises.
• If abnormal noises occur in use, stop the
operation of the air conditioner, and then con-
sult your dealer or our service station.
Regarding drainage of drain piping
• Is the drain piping executed to perform com-
plete drainage?
If proper drainage is not carried out from the out-
door drain pipes during air-conditioning opera-
tion, chances are that dust and dirt are clogged
in the pipe. This may result in a water leakage
from the indoor unit. Under such circumstances,
stop the operation of the air conditioner, and then
con sult your dealer or our service station.