7. OPTIMUM OPERATION

Observe the following precautions to ensure the
system operates.
• Adjust the room temperature properly for a com-
fortable environment. Avoid excessive heating or
cooling.
• Prevent direct sunlight from entering a room dur-
ing cooling operation by using curtains or blinds.
• Ventilate the room regularly.
Using the unit for long periods of time requires
attentive ventilation of the room.
• Do not place items that might be damaged by
water under the indoor unit.
Water may condensate and drip if the humidity
reaches 80% or if the drain exit gets clogged.
• Keep doors and windows closed. If the doors and
windows remain open, room air will flow out and
cause to decrease the effect of cooling and heat-
ing.
• Do not place other heaters directly below the
indoor unit.
They may deform due to the heat.
• Never place objects near the air inlet and the air
outlet of the unit. It may cause deterioration in the
effect or stop in the operation.
• Turn off the main power supply switch when it is
not used for long periods of time. When the main
power switch is turned on, some watts of electric-
ity is being used even if the system is not operat-
ing. Turn off the main power supply switch for
saving energy. When reoperating, turn on the
main power supply switch 6hours before opera-
tion for smooth running (Refer to MAINTE-
NANCE).
• When the display shows "
CLEAN AIR FILTER), ask a qualified service per-
son to clean the filters (Refer to MAINTE-
NANCE).
• Fully use the function of air flow direction adjust.
Cold air gathers on the floor, and warm air gath-
ers in the ceiling.
Set the air flow direction parallel during cooling or
dry operation, and set it downwards during heat-
ing operation.
Do not let the air blow directly to a person.
• It takes time for the room temperature to reach
the set temperature.
We recommend starting the operation in advance
using timer operation.
English
" (TIME TO
8. MAINTENANCE
(FOR SERVICE PERSONNEL)
ONLY A QUALIFIED SERVICE PERSON IS
ALLOWED TO PERFORM MAINTENANCE
WARNING
• Before touching any of connection wirings, be
sure to turn off all power supply switches.
• Contact professional personnel about attach-
ment of accessories and be sure to use only
accessories specified by the manufacturer.
If a defect results from your own workmanship, it
may result in water leaks, electric shock or fire.
CAUTION
• Before cleaning, be sure to stop unit opera-
tion, turn the breaker off or remove the power
cord.
Otherwise, an electric shock and injury may
result.
• Do not wash the air conditioner with water, as
this may result in electric shocks or fire.
• Consult your dealer regarding cleaning the
inside of the air conditioner.
Improper cleaning may cause breakage of plastic
parts, water leakage and other damage as well as
electric shocks.
Take care of scaffolding and exercise caution
when working high above ground level.
HOW TO CLEAN THE AIR FILTER
Clean the air filter when the display shows "
(TIME TO CLEAN AIR FILTER).
It will display that it will operate for a set amount of
time.
Increase the frequency of cleaning if the unit is
installed in a room where the air is extremely con-
taminated.
If the dirt becomes impossible to clean, change the
air filter (Air filter for exchange is optional)
1. Open the suction grille.
Push it downward slowly while pressing horizon-
tally the buttons provided on two spots.
(Follow the same procedure for closing.)
"