Installation Instructions

Brewer Setup
1. Review the dimensions for the unit and verify that it will fit properly in the space intended for it. Verify that
the counter or table will support the total weight of the brewer and dispensers when filled (specifics-page 3).
Allow a counter for a unit that is 19 ½ inches/495mm deep from front to the wall
2. Place the brewer on the counter or stand.
3. When the brewer is in position, level it front to back as well as side-to-side by adjusting the legs.
4. For Sweetener Delivery units, provide space near the TBS-2121 for the sweetener boxes
Water Connection
1. Water inlet is a ¼ inch male flare fitting.
2. Connect brewer to a cold water supply line only.
3. Install a water shut off valve near the brewer to facilitate service. An in-line water filter should be used,
it should be installed after the water shut off valve and in a position to facilitate filter replacement.
4. Flush the water supply line and filter before connecting it to the brewer
5. Verify that the water line will provide at least 1½gpm (5.7lpm) per minute and also that the water
pressure is between 35-50 psig (241-345kPa) before connecting it to the brewer.
6. Note that during use all water filters will clog and will slow the water flow. The reduced water flow
affects the operation of the TBS-2121. Always schedule changing water filters per the manufactures
specification.
7. Unit was calibrated to a stable, non-fluctuating water supply at 45 psi. Unit may require a pressure
regulator OR calibration for other water pressures. See "Dill. Volume" setting in "PROGRAMMING"
menu
Electrical Connection
1. Verify that the actual voltage at the electrical service connection is compatible with the specifications on
the brewer's serial number label.
2. Plug in unit into an appropriate 120v circuit. Note that the plug is either a NEMA 5-15P or NEMA 5-20P.
The NEMA 5-15P is for a minimum 15 amp circuit the NEMA 5-20P a minimum 20 amp circuit [USA].
3. The temperature and the fill level of the water tank are pre-set at the factory. There is no need to turn
off the heaters during the installation process. The control board automatically disables the heaters until
the tank is full of water. The heating process will start automatically when the tank has filled with water.
Warning: To prevent
electrical shock, this
unit must be properly
grounded.
Features of your FETCO Brewer
Touch-screen for brewer operation
Brew basket sensor (not accessible)
SD card interface port (Load & Save)
Three Position Brew Basket
Dilution shelf-[behind brew basket ]
Removable back panel for service
Main power switch
Platform for two slim-line dispensers
WARNING—DANGER
Do
not
plug-in
energize this equipment, or attempt
operation without all covers in place
6
and all screws fastened
or