Connecting The Keyboard, Mouse, And Monitor Calibration Device; Connecting Storage - HP XW8400 Manual

With autodesk lustre 2009
Hide thumbs Also See for HP XW8400:
Table of Contents

Advertisement

2
Connecting Peripherals
Connecting the Keyboard, Mouse, and Monitor Calibration
Device
Connect the mouse, keyboard, and monitor calibration device to the workstation via the 4-port
USB extender (TP.USB-EXT-400).
To connect the keyboard and mouse:
Connect the USB keyboard to port 2 on the remote unit of the USB extender.
1.
Connect the USB mouse to port 3 on the remote unit of the USB extender.
2.
Connect the monitor calibration device (TP.MON-CAL-LCDCRT) to port 4 on the remote
3.
unit of the USB extender.
Use an RJ-45 cable to connect the remote unit of the USB extender to the local unit of the
4.
USB extender.
Connect the local unit of the USB extender to USB1 port on the workstation.
5.
To enable the Eye-One calibration utility driver:
Do one of the following:
For Windows-based workstations, if the driver is not already installed, you will be
prompted to install the monitor calibration device driver when you restart the
workstation. The driver is available from the C:\Program Files\Autodesk\Lustre Color 2008
SP3\Calibration\drivers directory.
For Linux workstations, once the software installation has been completed,start the
eyeone27 daemon on the workstation. Type: /etc/init.d/eyeoned_2009 start

Connecting Storage

The storage connections for your system depend on whether you are running Lustre on the
Windows or Linux operating system.
Storage for Windows-Based Workstations
Your workstation is configured with a 4-port ATTO Celerity FC-44ES fibre channel adapter. See
"Connection Diagram for the HP xw8400"
and connections.
18
on page 16 for the fibre channel adapter location

Advertisement