Whirlpool W10526086A Installation Instructions Manual page 13

30" (76.2 cm) double oven dual fuel ranges
Table of Contents

Advertisement

Available languages

Available languages

3. Pull the conduit through the strain relief on cord/conduit plate
on bottom of range. Allow enough slack to easily attach
wiring to the terminal block.
A
G
F
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Line 2 (red) wire
4. Attach terminal lugs (located in the package containing
literature) to line 1 (black), neutral (white), and line 2 (red)
wires. Loosen (do not remove) the setscrew on the front of
the terminal lug and insert exposed wire end through bottom
of terminal lugs. Securely tighten setscrew to XX lbs-in.
torque. See Bare Wire Torque Specifications chart.
C
D
A. Terminal lug
B. Setscrew
C. Line 1 (black) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
Wire Awg
8 gauge copper
6 gauge aluminum
5. Use Phillips screwdriver to connect the bare (green) ground
wire to the range with the ground-link screw. The ground wire
must be attached first and must not contact any other
terminal.
B
C
D
E
E. Neutral (white) wire
F. Line 1 (black) wire
G. Bare (green) ground wire
A
B
E
D. Neutral (white) wire
E. Line 2 (red) wire
Torque
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
6. Use
" nut driver to connect the neutral (white) lug to the
center terminal block post with one of the 10-32 hex nuts.
A
B
C
A. 10-32 hex nut
B. Line 1 (black)
C. Bare (green) ground wire
D. Ground-link screw
7. Connect line 1 (black) and line 2 (red) terminal lugs to the
outer terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
3-wire connection: Direct Wire
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
1. Pull the conduit through the hole and conduit plate on bottom
of range. Allow enough slack to easily attach the wiring to the
terminal block.
A
F
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
G
F
D
E
E. Neutral (white) wire
F. Line 2 (red)
G. Terminal lug
B
C
D
E
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
13

Advertisement

Table of Contents
loading