Kenmore 795.77562600 Service Manual page 41

Table of Contents

Advertisement

Enter the TEST 3 MODE
Is the voltage between
Pins 4 and pin 12 of
CON3 like as below?
CON3
Pin12
Pin4
BK
BL
Voltage of Compressor
Test Point
Ressult
pin4 to pin12
115 V
Yes
Replace
Yes
Damper
- 41 -
After reset the unit, take steps to PCB as follows
for temperature compensation.
1. In the case of 6871JB1431 ( by July 2007)
: Compensate with replacing RCR1
RCR1
Temp. Compension
180 k‰
+ 2.5 deg
56 k‰
+ 2 deg
33 k‰
+ 1.5 deg
18 k‰
+ 1 deg
12 k‰
+ 0.5 deg
* Change RCR1
2. In the case of EBR34917102
(from Aug 2007)
: Compensate with Jump wire cutting
JUMP WIRE
Temp. Compensation
JCR1
JCR2
Cutting both jumpers affords a 2...
temperature compensation
* Cutting of jumper wire
Ressult
Current
Colder
+ 1.0 deg
+ 1.0 deg

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents