Is the resistance value
between pins 10(WH)
And 4(BL) of CON3
like as below?
Resistance
Test Point
(1) To (2)
No
Is the connection loose?
No
Is the resistance value
of Fuse –M like
as below?
(1) BL
(2) BN
Open or Short of Fuse-M
Test Point
(1) To (2)
Yes
Normal
Yes
pin10 WH
pin4 BL
Ressult
34 ~ 42
Reconnect
Yes
Replace
No
Fuse-M
Ressult
0
- 23 -
Is the resistance value of
heater like as below?
Heater Resistance
Test Point
(1) To (2)
Yes
Is the resistance
value of DEF-sensor like
as below? It depends on
the temperature.
Defrost Sensor Resistance
Test Point
Result
-30 C
129.3 k
-20 C
76.96 k
-10 C
47.34 k
0 C
30 k
Yes
Explain to the customer! :
It can be occurred, when the gasket is not
stuck to product or when you put the high
temperature loads (hot foods) a lot
in the product.
Replace
No
Heater
(1)
(2)
Ressult
34 ~ 42
Replace
No
DEF-sensor
(1) BO
(2) BO
Test Point
Result
10 C
19.53 k
20 C
13.03 k
30 C
8.896 k
40 C
6.201 k