PACKAGE COOLING SPECIFICATIONS

COOLING CAPACITY, BTUH
COOLING
CAPACITY
SEER / EER
UNIT
VOLTAGE (NAMEPLATE)
AMPS (TOTAL)
ELECTRICAL
SPECIFICATION
MINIMUM CIRCUIT AMPACITY
MAXIMUM OVERCURRENT PROTECTION
COMPRESSOR
TYPE
RATED LOAD AMPS
LOCKED ROTOR AMPS
CONDENSER
HORSEPOWER
RPM
FAN MOTOR
FULL LOAD AMPS
LOCKED ROTOR AMPS
BLADE DIAMETER (INCHES) / NUMBER OF BLADES
CONDENSER FAN
CONDENSER
FACE AREA - SQ. FT.
COIL
NUMBER OF ROWS
FINS PER INCH
HORSEPOWER - NO. OF SPEEDS
EVAPORATOR
FULL LOAD AMPS
BLOWER
MOTOR
LOCKED ROTOR AMPS
MOTOR SPEED TAP - COOLING
RPM
EVAPORATOR
DIAMETER X W IDTH (INCHES)
HI EFFICIENCY COOLING CFM
BLOWER
5 TON NOMINAL COOLING CFM
FAN ONLY COOLING CFM
MAX EXTERNAL STATIC PRESS ("w.c.)
EVAPORATOR
FACE AREA - SQ. FT.
NUMBER OF ROWS
COIL
FINS PER INCH
GENERAL
FILTER SIZE - SQ. FT. *
DRAIN SIZE (INCHES)
INFORMATION
EXPANSION DEVICE
REFRIGERANT CHARGE R-410A (Oz.)
POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES)
LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES)
SHIPPING WEIGHT LBS.
OPERATING WEIGHT LBS.
(1)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
*
Calculated external filter size based on air velocity of 300 ft/min.
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.
All wires and overcurrent protection devices are sized for use with electric heaters only and without
WARNING
WARNING
refrigeration.
PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent
protection during refrigeration cycle.
8
(1)
If heaters are not installed with above wire size, overheating and fire could occur. See
GPC14[24-36]H41A*
GPC1424H41*
GPC1430H41*
24,600
28,400
14.5 / 12.1
14.0 / 12.0
208-230/1/60
208-230/1/60
10.5
13.16
12.5
15.6
20
25
RECIP
RECIP
7.9
9.8
41
55
1/6
1/4
815
830
1.1
1.5
1.7
3.0
22 / 3
22 / 3
13.4
13.4
1
1
24
24
1/2 - 5
1/2 - 5
1.5
1.86
NA
NA
T2
T2
1050
1050
10 X 8
10 X 8
850
1,050
NA
NA
800
950
0.5
0.5
5.25
4.67
3
4
16
16
20 x 20 x 1
20 x 25 x 1
3/4"
3/4"
ORIFICE (0.057)
ORIFICE (0.060)
83
78
3/4, 1, 1-1/4
3/4, 1, 1-1/4
1/2
1/2
310
310
300
300
GPC1436H41*
35,600
14.0 / 12.0
208-230/1/60
20.06
24.2
40
SCROLL
16.7
79
1/4
830
1.5
3.0
22 / 3
13.4
1
24
1/2 - 5
1.86
NA
T2
1050
10 X 8
1,200
NA
1,100
0.5
5.2
3
14
25 x 25 x 1
3/4"
ORIFICE (0.065)
80
3/4, 1, 1-1/4
1/2
370
360