GPC/GPH 13 SEER "H" SERIES
ATTENTION INSTALLING PERSONNEL
IMPORTANT NOTE: These units are shipped WITHOUT REFRIGERANT and are pressurized with a
nitrogen holding charge which must be removed prior to system charging and start up.
Prior to installation, thoroughly familiarize yourself with this Installation Manual. Observe all safety warnings.
It is your responsibility to install the product safely and to educate the customer on its safe use.
These installation instructions cover the outdoor installation of self con-
tained package air conditioner and heating units. See the Specification
Sheets applicable to your model for information regarding accessories.
IO-390A
6/2011
I
NSTALLATION
F
S
-C
OR
ELF
ONDITIONERS AND
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
All information contained herein is subject to change without notice.
During installation or repair, caution is to be observed.
Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com
© 2010 - 2011 Goodman Manufacturing Company, L.P.
I
NSTRUCTIONS
P
ONTAINED
H
EAT
www.amana-hac.com
ACKAGE
P
U
UMP
NITS
*NOTE: Please contact your distributor
or our website for the applicable
Specification Sheets referred to in
this manual.

Advertisement

Table of Contents
loading

Summary of Contents for Goodman GPC 13 SEER H Series

  • Page 1 Sheets applicable to your model for information regarding accessories. Specification Sheets referred to in this manual. Goodman Manufacturing Company, L.P. IO-390A 5151 San Felipe, Suite 500, Houston, TX 77056 6/2011 www.goodmanmfg.com www.amana-hac.com © 2010 - 2011 Goodman Manufacturing Company, L.P.
  • Page 2: Table Of Contents

    INDEX ADJUSTING SPEED TAP FOR INDOOR BLOWER MOTOR ............11 INTRODUCTION ............2 Checking Product Received ......... 2 CHECKING CHARGE ..........11 Message to the Homeowner ........2 ELECTRIC HEAT INSTALLATION & ADJUSTMENT ... 12 Before Beginning Installation ........2 MAINTENANCE ............
  • Page 3: Service Parts Department

    CONSUMER AFFAIRS WARNING GOODMAN MANUFACTURING COMPANY, L.P. 7401 SECURITY WAY O PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH, DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHER HOUSTON, TEXAS 77040 FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLIANCE.
  • Page 4: Clearance

    • Structural strength of supporting members • Clearances and provision for servicing • Power supply and wiring • Air duct connections • Drain facilities and connections 10" • Location may be on any four sides of a home, 36" WALL manufactured or modular, to minimize noise Clearance The unit is designed to be located outside the building with...
  • Page 5: Connecting The Return And Supply Flexible Duct

    Ducting work should be fabricated by the installing contractor SQUARE TO ROUND DUCT CONVERTER PANEL in accordance with local codes. Industry manuals may be used as a guide when sizing and designing the duct system- such as NESCA (National Environmental Systems OUTER FLANGE BEAD Contractors Association, 1501 Wilson Blvd., Arlington,...
  • Page 6: Wiring

    Install condensate drain trap as shown. Use ¾ “ drain WARNING connection size or larger. Do not operate without trap. Unit must be level or slightly inclined toward drain. HIGH VOLTAGE ISCONNECT POWER BEFORE SERVICING OR INSTALLING WIRING THIS UNIT. ULTIPLE POWER SOURCES MAY BE PRESENT.
  • Page 7: Operation

    For branch circuit wiring (main power supply to unit Turn on the electrical supply at the disconnect. disconnect), the minimum wire size for the length of the Turn the fan switch to the “ON” position. The blower should run can be determined from Table 4 using the circuit operate after a 7 second delay.
  • Page 8: Final System Checks

    15. If checking the unit in the wintertime, when the outdoor coil The foregoing “Start-up Procedure and Check List” is is cold enough to actuate the defrost control, observe at recommended to serve as an indication that the unit will least one defrost cycle to make sure the unit defrosts operate normally.
  • Page 9: Compressor

    Compressor - This item is activated by the contactor for When the heat pump is on the heating cycle, it is necessary heating and cooling, except during emergency heat. It is to redirect the refrigerant flow through the refrigerant circuit protected by an internal overload.
  • Page 10: Air Flow Measurement And Adjustment

    calls for heat. At the end of the timing period, the unit’s When the unit’s defrost thermostat has closed, short the test pins on the defrost board until the reversing valve shifts, defrost cycle will be initiated provided the sensor remains indicating defrost.
  • Page 11: Adjusting Speed Tap For Indoor Blower Motor

    After unit is set and ducted, verify ESP with a 1" inclined Saturated Suction Suction Pressure manometer with pitot tubes or a Magnahelic gauge and Temperature (°F) confirm CFM to blower curves in the specification sheets. All units have three speed blower motors. If low speed is not utilized, the speed tap can be changed to medium or high speed.
  • Page 12: Electric Heat Installation & Adjustment

    Outside Air Into Return Duct ELECTRIC HEAT INSTALLATION & ADJUSTMENT Do not introduce cold outside air into the return duct of a This series of electric cooling and heat pump package heat pump installation. Do not allow air entering the indoor equipment is designed to accept a field installed electric coil to drop below 65°...
  • Page 13: Troubleshooting Chart

    TROUBLESHOOTING CHART HIGH VOLTAGE! ISCONECT POWER BEFORE SERVICING OR INSTALLING THIS UNIT ULTIPLE POWER WARNING SOURCES MAY BE PRESENT AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH POSSIBLE CAUSE REMEDY SYMPTOM High head - low suction a.
  • Page 14: Wiring Diagrams

    GPC13(36)H21** WIRING DIAGRAM NOTE #4 EBTDR SEE NOTE #6 XFMR-R XFMR-C SPEED LVJB RCCF (IF USED) SEE NOTE 5 (TRANS240V) (M1) RD CONTROL (COM) HIGH 3 SPEED 2 SPEED OPTIONAL COMP NOTE #3 SUPPLY VOLTAGE 208-240/1/60 COMPONENT LEGEND FACTORY WIRING SEE NOTE #3 LINE VOLTAGE BLOWER INTERLOCK RELAY...
  • Page 15 GPC13(60)H21** WIRING DIAGRAM NOTE #3 SEE NOTE 5 LVJB RCCF (IF USED) SEE NOTE 4 CONTROL COMP SEE NOTE 2 COMPONENT LEGEND FACTORY WIRING SUPPLY VOLTAGE LINE VOLTAGE CONTACTOR 208-240/1/60 LOW VOLTAGE CONDENSER MOTOR OPTIONAL HIGH COMP COMPRESSOR VOLTAGE EVAPORATOR MOTOR EQUIPMENT GROUND FIELD WIRING LVJB...
  • Page 16 GPH13(36)H21** WIRING DIAGRAM NOTE #4 EBTDR SEE NOTE #6 XFMR-R XFMR-C NOTE #2 SPEED LVDR LVJB BUSHING R RD HVDR RCCF (IF USED) SEE NOTE #5 (TRANS240V) (M1) RD CONTROL (COM)BK HIGH 3 SPEED 2 SPEED OPTIONAL COMP NOTE #3 SUPPLY VOLTAGE 208-240/1/60 COMPONENT LEGEND...
  • Page 17 GPH13(60)H21** WIRING DIAGRAM NOTE #3 SEE NOTE 5 LVJB LVDR HVDR RCCF SA (IF USED) SEE NOTE 4 CONTROL RD RD COMP SEE NOTE 2 COMPONENT LEGEND FACTORY WIRING SUPPLY VOLTAGE LINE VOLTAGE CONTACTOR 208-240/1/60 LOW VOLTAGE CONDENSER MOTOR OPTIONAL HIGH COMP COMPRESSOR VOLTAGE...
  • Page 18 THIS PAGE LEFT BLANK INTENTIONALLY...
  • Page 19 THIS PAGE LEFT BLANK INTENTIONALLY...
  • Page 20 That’s why we know. . .There’s No Better Quality. Visit our website at www.goodmanmfg.com or www.amana-hac.com for information on: • Products • Parts • Warranties • Contractor Programs and Training • Customer Services • Financing Options © 2010 - 2011 Goodman Manufacturing Company, L.P.

This manual is also suitable for:

Gph 13 seer h series

Table of Contents