LOCATION OF YOUR WASHER
Do Not Install
the Washer:
1. In an area exposed to dripping water or outside
weather conditions. The ambient temperature
should never be below 60°F (15.6°C)for proper
washer operation.
2. In an area where it will come in contact with curtains or
drapes.
3.On carpet. The floor MUST be a hard surface with
a maximum slope of 1/2" per foot (1.27 cm per
30 cm). To make sure the washer does not vibrate
or move, you may have to reinforce the floor.
NOTE: If floor is in poor condition, use 3/4" impregnated
plywood sheet solidly attached to existing floor covering.
IMPORTANT:
Minimum
Installation
Clearances
. When installed in alcove: Sides, Rear,
Top = O" (0 cm)
. When installed in closet: Sides, Rear,
Top = O" (0 cm), Front = 1" (2.54 cm)
• Closet door ventilation openings required:
2 louvers each 60 square in. (387 cm), located 3"
(7.6 cm) from top and bottom of door
ROUGH-IN
DIMENSIONS
FRONT
28"
(73.6cm)
(99cm)
SIDE
/
35"
(88.9cm)
*NOTE:
With Legs: 40 1/2" (102.5 cm) - (5/4" (1.9 cm) adjustability)
With Built-In RiserTM: 4 6" 1116.9 cm) - (5/4" 11.9cm) adjustability)
With Optional Pedestal IGF×P:1308): 52" (152.1 cm) - (3/4" (1.9 cm)
adjustability)
Stacked: 78 1/4" (198.8 cm)
19