2.14 Diagnostic Sequence

You can check the ATA Board for proper operation as follows. The self test does not require
operator intervention. It runs automatically when the power is placed on at regular intervals or on
operator demand.
1. Press [MENU], [0], [0], [0], [0].
2. Press the [2] key twice to start the diagnosis sequence. The results of the test appear as
shown below.
FR-1500 M-3 TEST
1. Program No.
03591521**
2. ROM Check
OK
3. RAM Check
OK
4. Antenna Rotation
5. TX Trigger Frequency
6. Video Level
000
7. Video Signal
OK
ARP TEST
1. Program No.
18590411** 18590421**
2. ROM Check
OK
3. RAM Check
OK
4. Speed Log
OK 0.0KT
5. Course
OK
6. Trigger
OK
7. Video Signal
OK
8. Bearing Pulse OK
9. Heading Pulse OK
10. Minimum Hit OK
11. Scan Time
0274
12. Manual Acq
00
13. Auto Acq
00
14. FE-Data 1
0000
15. FE-Data 2
0000
If NG appears for any ATA-related item, call for service.
Press MENU key to escape.
Press ENTER to check CRT.
** = Program Version No.
24rpm
3000Hz
OK
-2.14-