Wire Spool Installation

1. Turn the welder OFF and unplug
it before proceeding.
2. Pull up on the door latch,
then open the Door.
3. Remove the Spool Knob, Spool Spring, and upper
Spool Plate. If replacing a Spool, remove the old
Spool and all remaining wire from the liners.
4. Place the new Wire Spool over the Spool Spindle
and on top of the lower Spool Plate as illustrated.
To prevent wire feed problems, set the
Spool so that it will unwind clockwise.
5. Secure Spool in place with the upper Spool Plate
(narrower end against the Spool),
then the Spool Spring and Spool Knob.
SKU 68885
MIG 170
WIRE FEED WELDER
.023"-.035"
Wire
(Tip and roller change required)
Capacity 22 Ga. – 1/4" Steel Plate
Material
Mild Steel and Stainless Steel
Types
(Not for welding Aluminum.)
For technical questions, please call 1-800-444-3353.
I
O
ITEM 68885
WIRE FEED SPEED
240V~
20A
Door
door
latch
wire must
unwind this
direction
Spool Knob
Spool Spring
Upper
Spool Plate
Wire Spool
Lower
Spool Plate
Spool Spindle