Air-to-water heat pump for indoor installation (36 pages)
Summary of Contents for Dimplex LI 11TER+
Page 1
LI 11TER+ LI 16TER+ Montage- und Gebrauchsanweisung Installation and Operating Instructions Instructions d’installation et d’utilisation Reversible Reversible Pompe à chaleur Luft/Wasser- Air-to-Water air-eau réversible Wärmepumpe für Heat Pump for pour installation Innenaufstellung Indoor Installation intérieure Bestell-Nr. / Order no. / N de commande : 452160.66.16 FD 8611...
Please Read 1.3 Energy-Efficient Use of the Immediately Heat Pump With the purchase of this heat pump you are helping to protect the environment. A prerequisite for energy-efficient operation is 1.1 Important Information the correct design of the heat source system and heating (radia- tors and circulation pump) or cooling system.
Pressure switches The waste heat can also be used for hot water consumers, such Liquifier (heating operation) as domestic hot water, swimming pool or bathroom heating, via Compressor the additional heat exchanger. www.dimplex.de...
Transport 3.2 Switch Box The switch box is located in the heat pump. It can be swung out ATTENTION! after removing the lower front cover and loosening the fastening When transporting the heat pump, ensure that it is not tilted more than screw located in the upper right-hand corner.
There should be no contact with the external sheeting. Installed air ducts should be sound-isolated from the heat pump to prevent the transmission of solid-borne sound to the ducts. www.dimplex.de...
Antifreeze A method of manual drainage (see illustration) should be pro- vided for heat pumps which are exposed to frost. The antifreeze function of the heat pump controller is active whenever the con- troller and the heat circulating pump are ready for operation. If the heat pump is taken out of service or in the event of a power failure, the system has to be drained.
The limit temperature on the heat pump controller should temperature. The temperature spread should be measured as also be turned up to 15 °C. close as possible to the heat pump. The heating element of mono energy systems should be disconnected. www.dimplex.de...
Maintenance / Cleaning 8.3 Cleaning the Air System Air ducts, evaporator, ventilator and condensate outflow should 8.1 Maintenance be cleaned of contamination (leaves, twigs, etc.) before each new heating period. Do this by opening the front of the heat To protect the paintwork, avoid leaning anything against the de- pump.
The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature and 55 °C heating water flow temperature. 3. See CE declaration of conformity 4. The heat circulating pump and the heat pump controller must always be ready for operation. www.dimplex.de...
3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung Standardregler / Control of the standard controller / Commande régulateur standard A-VIII...
Pièces à fournir par le client - - - - - bauseits bei Bedarf anzuschließen To be connected by the customer as required à raccorder par le client au besoin ––––– werksseitig verdrahtet Wired ready for use câblé départ usine www.dimplex.de A-XIII...
Sonde de retour 2e circuit de chauffage Vorlauffühler Flow sensor Sonde aller Elektroverteilung Electrical distribution system Distributeur courant électrique Kaltwasser Cold water eau froide Mischer AUF Mixer OPEN Mélangeur OUVERT Mischer ZU Mixer CLOSED Mélangeur FERME Warmwasser Domestic hot water Eau chaude www.dimplex.de A-XV...
5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité A-XVI...
Page 27
Glen Dimplex Deutschland GmbH Irrtümer und Änderungen vorbehalten. Geschäftsbereich Dimplex Subject to alterations and errors. Am Goldenen Feld 18 Sous réserve d’erreurs et modifications. D-95326 Kulmbach +49 (0) 9221 709 565 www.dimplex.de...