FR-7112
FR-7252
7. DIMENSIONS AND MASS
8. CORTING COLOR
(1) Display Unit
(2) Scanner Unit
9. COMPASS SAFE DISTANCE
(1) Display Unit
(2) Scanner Unit
FR-7062/7112
FR-7252
10. ARP MODULE (OPTION)
(1) Acquisition Range
(2) Tracking Range
(3) Maximum Number of Target 10
(4) Acquisition Time
(5) Alarm Timing
(6) Vector Length
(7) Plotting Interval
(8) Numeric Data Indication
(9) Acquisition Available Speed 100 kt relative
XN13A(24rpm): 80 W to 120 W(100 kt)
XN12A(24rpm): 85 W to 100 W(100 kt)
XN12A(48rpm): 95 W to 120 W(70 kt)
XN13A(24rpm): 90 W to 130 W(100 kt)
XN12A(24rpm): 105 W to 125 W(100 kt)
XN12A(48rpm): 120 W to 140 W(70 kt)
XN13A(24rpm): 115 W to 150 W(100 kt)
See Outline Drawings
Panel: N3.0
Chassis: 2.5GY5/1.5
N9.5
Standard: 1.1 m
Standard: 1.0 m
Standard: 1.7 m
0.2 to 16 NM
0.1 to 16 NM
Within 5 sec (scanner rotation: 24 rpm)
Lost target (blink mark, collision alert)
30 sec; 1, 3, 6, 15 or 30 min (selected on menu)
15, 30 sec; 1, 2, 3 or 6 min (selected on menu)
Distance, Bearing, Course, Speed, CPA, TCPA
SP - 4
Steering: 0.8 m
Steering: 0.8 m
Steering: 1.3 m