LG DLE2150W User's Manual & Installation Instructions page 15

Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRU€TIONS
VENTING THE DRYER (cont.)
DuCtwOrk
Recommended
(10.2
cm)
(10.2
cm)
Use Only for Short
Run Installations
(6.35 era)
0
1
2
3
4
0
1
2
3
4
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (13.7 m)
36 ft. (11.0
m)
28ft._
55 ft. (16.8 m)
47 ft. (13.7 m)
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)
NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended
to use more than four 90 ° elbows.
ROuting
and Connecting
Ductwork
Follow the guidelines below to maximize drying
performance
and reduce lint buildup and
condensation
in the ductwork.
NOTE: Ductwork and fittings are NOT included
and must be purchased separately.
• Use 4-in. (10.2 cm) diameter rigid or semirigid
metal ductwork.
• The exhaust duct run should be as short as
possible.
• Use as few elbow joints as possible.
• The male end of each section of exhaust duct
must point away from the dryer.
• Use duct tape on all duct joints.
• Insulate ductwork that runs through unheated
areas in order to reduce condensation
and lint
buildup on duct surfaces.
iMPORTANT:
Failure to exhaust the dryer
correctly will void the dryer's warranty.
f_
Correct Venting
i
_\
./'
f= \
I;
I?'
R,
incorrect Venting
15

Advertisement

Table of Contents
loading

Table of Contents