Cleaning The Burner Tubes - Kenmore 141.16686 Operator's Manual

Gas grill
Table of Contents

Advertisement

Toreduce t he chance o fFLASHBACK
FIRE youmust
clean theBurner Tubes a sfollows atleast o nce a month
insummer andfallor whenever spiders a reactive inyour
area, a ndif your g rill h asnotbeen used foranextended
period oftime.
1. Turn allBurner Valves t othefullOFF position.
2. Turn theLPGas tank valve t othefullOFFposition.
ForNatural Gas shut o ffNGvalve.
3. Detach theLPGas regulator assembly from your
gasgrill. F orNatural Gas detach N Gregulator from
your g rill.
4. Remove theCooking Grids, Savor Plates
TM
and
Grease
Trays from your
grill.
5. Remove
the screw(s)
from the rear of each Burner
and the Infra-red
Burner
using a Phillips
Head
Screwdriver.
6. Carefully
lift each Burner
up and away from the
Gas Valve Orifice.
7. Check
and clean burner/venturi
tubes for insects
and insect
nests. A clogged
tube
can lead to a fire
beneath
the grill.
8. Refer to Figure
1 and perform
one of these
three cleaning
methods:
[]
METHOD
1: Bend
a stiff
wire
or wire
coat
hanger
into
a small
hook
as shown
and
run
the hook
through
the
Burner
Tube
and
inside
the
Burner
several
times
to remove
debris.
,)
[]
[]
METHOD
2: Use
a bottle
brush
with
a
flexible
handle
and
run
the brush
through
the
Burner
Tube
and
inside
the
Burner
several
times
to remove
any
debris.
METHOD
3: Use
an air hose
to force
air
through
each
Burner
Tube.
The
forced
air
should
pass
debris
or obstructions
through
the
Burner
and
out the Ports.
Figure
1
Regardless
of which
Burner
cleaning
procedure
you use,
we recommend
you also complete
the following
steps
to
help prolong
Burner
life.
1.
After each
use of the main grill or infra-red
cooking
zone it is necessary
to burn off food
particles
and
drippings
which
can clog Burner
ports
and reduce
Burner
performance.
OPEN
the grill Lid, ignite the
burner(s)
and operate
grill on HIGH
setting
for 3 to 5
minutes.
You can close
the Lid if only main Burners
are lit, but NEVER
close
the Infra-red
Sear Burner
Lid
over a lit Infra-red
Burner.
2.
3.
Use a nylon brush,
blower
or vacuum
to remove
accumulated
ash from the outer surface
of each
Burner.
Clogged
tube
style Burner
ports
can be
cleaned
with
a stiff wire, such
as an open
paper
clip.
DO NOT use a stiff brush
or sharp
tool of any type on
the fragile
infra-red
Burner.
Inspect
each
Burner
for damage
(cracks
or
holes)
and if such damage
is found,
order
and
install a new Burner.
After
installation,
check
to ensure
that the Gas Valve Orifices
are
correctly
placed
inside
the ends of the Burner
Tubes.
Also
check
the position
of your Spark
Electrode.
For
safe
operation
ensure
the Gas
Valve
Assembly
Orifice
is inside
the
Burner
Tube
before
using
your
grill.
See
figure.
If the
Orifice
is not inside
the
Burner
Tube,
lighting
the
Burner
may
cause
explosion
and/or
fire
result-
ing
in serious
bodily
injury
and/or
property
damage.
Tube
Burner
Gas VaIve AssembIy
Orifice
BurnerTube
TO CLEAN
BURNER
TUBE,
INSERT
HOOK
AS INDICATED
BY THE ARROW
22

Advertisement

Table of Contents
loading

This manual is also suitable for:

141.17686141.17692