Target Alarm; How To Set A Target Alarm - Furuno FAR-2107(-BB) Operator's Manual

Far-2807 series; far-2107 series; far-2107-bb series
Hide thumbs Also See for FAR-2107(-BB):
Table of Contents

Advertisement

1.23

Target Alarm

The target alarm serves to alert the navigator to targets (ships, landmasses, etc.)
entering a specific area, with audiovisual alarms.
The target alarm zone has a fixed width of 0.5 nm in the radial direction (depth)
and is adjustable from 3.0 to 6.0 nm (guard zone 1) and any distance (guard
zone 2). On the Non-IMO radar the boundaries can be set at any distance. On
any radar type the sector of the zone can be set from 0 to 360 degrees in any
direction.
1.23.1

How to set a target alarm

The procedure below shows how to set a target alarm using the figure below as
an example.
1. Left-click ALARM1 or ALARM2 box, whichever alarm you wish to put the
cursor jumps into the effective display area and "SET" appears inside the
ALARM box selected.
2. Use the trackball to put the cursor on point "A" then push the left button.
3. Use the trackball to put the cursor on point "B" then push the left button.
"WORK" replaces "SET" in the ALARM box. The target alarm zone's lines are
shown in dashed lines.
000
350
340
330
320
310
300
A
290
280
270
260
250
240
230
220
210
200
190
180
CAUTION
• The alarm should not be relied upon as
the sole means for detecting possible
collision situations.
• A/C SEA, A/C RAIN and GAIN controls
should be properly adjusted to be sure
the alarm system does not overlook
target echoes.
ALARM 1
ALARM 2
Target alarm zone
010
020
030
040
Other alarm zone examples
050
060
070
B
080
Point A
X
090
100
110
120
130
140
150
160
170
Target alarm zone
ALARM boxes
Point B
X
X
Point B
1. RADAR OPERATION
Point A
X
X
X
Point A
Point B
1-39

Hide quick links:

Advertisement

Table of Contents
loading