  • Page 1 Digital Blood Pressure Monitor Model UA-851 Instruction Manual Manuel d ’ instructions Manual de Instrucciones Manuale di Istruzioni Bedienungsanleitung 使用手册 1WMPD4001437A...
  • Page 2: Table Of Contents

    Contents Dear Customers..............2 Preliminary Remarks ............. 2 Precautions................2 Parts Identification..............3 Symbols................4 Operation Mode..............5 Using The Monitor ..............6 Installing / Changing The Batteries ........6 Connecting The Air Hose ..........6 Connecting The AC Adapter ..........6 Selecting The Correct Cuff ..........
  • Page 3: Dear Customers

    Dear Customers Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. We recommend that you read through this manual carefully before using the device for the first time.
  • Page 4: Parts Identification

    Parts Identification Display Air Connector Plug Arm Cuff START Button Air Socket Air Hose (Blue illumination) Battery Compartment Battery Cover 1.5V Batteries DC Jack (R6P, LR6 or AA) Part of Display MEMORY Systolic Pressure Pressure Bar Indicator WHO Classification Indicator Diastolic Pressure Heart Mark Pulse Rate...
  • Page 5: Symbols

    Symbols Symbols Function / Meaning Recommended Action Standby and turn the device on. Battery installation guide Direct current Serial number Date of manufacture Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks. The indicator that appears while Measurement is in measurement is in progress.
  • Page 6: Operation Mode

    Operation Mode 1. Normal Measurement With Storing Data (Refer to page 9) Press the START button. Blood pressure is measured and data are stored within the device. The device can store the last ninety sets of data in memory automatically. 2.
  • Page 7: Using The Monitor

    Using The Monitor Installing / Changing The Batteries 1. Slide the battery cover to open it. Step 2 2. Remove the used batteries and insert batteries into battery compartment as shown, taking care that the polarities (+) and (-) are correct. 3.
  • Page 8: Selecting The Correct Cuff

    UA-CUFDBKAU-EC Small cuff - - Arm size: The circumference at the biceps. Note: This UA-851 monitor is NOT designed for using a small cuff. Rolled up shirtsleeve Attaching The Arm Cuff 1. Wrap the cuff around the upper arm, Cuff about 2 - 3 cm above the elbow, as shown.
  • Page 9: How To Take Proper Measurements

    Using The Monitor How To Take Proper Measurements For the most accurate blood pressure measurement: Sit comfortably at a table. Rest your arm on the table. Relax for about five to ten minutes before measurement. Place the center of the cuff at the same height as your heart. Remain still and keep quiet during measurement.
  • Page 10: Measurements

    Measurements Model UA-851 is designed to detect the pulse and to inflate the cuff to a systolic pressure level automatically. If your systolic pressure is expected to exceed 230 mmHg, read "Measurement With The Desired Systolic Pressure" on the next page.
  • Page 11: Measurement With The Desired Systolic Pressure

    Measurements Measurement With The Desired Systolic Pressure If your systolic pressure is expected to exceed 230 mmHg, use this procedure. Place the cuff on the arm (preferably the left arm). At heart level Press and hold the button. START Release the button when the average Press and hold the button START of all the data in memory is displayed.
  • Page 12: Recalling Memory Data

    Recalling Memory Data Note: This device stores the last ninety measurements in memory. The data are retained as long as the batteries are in the device. When you remove the batteries or the batteries are drained, the data will be erased. Press and hold START 1.
  • Page 13: What Is An Irregular Heartbeat

    What Is An Irregular Heartbeat The device provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeats during the blood pressure measurement.
  • Page 14: About Blood Pressure

    About Blood Pressure What Is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts. Diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg).
  • Page 15: Troubleshooting

    described in this manual to get to know your normal blood pressure. Regular readings give a more comprehensive blood pressure history. Be sure to note date and time when recording your blood pressure. Consult your doctor to interpret your blood pressure data.
  • Page 16: Maintenance

    However it is generally recommended to have the monitor inspected every 2 years, to ensure proper functioning and accuracy. Please contact either your authorized dealer or A&D for maintenance. Technical Data Type UA-851 Measurement method Oscillometric measurement Measurement range Pressure: 20 - 280 mmHg...