SYSTEM CHECKOUT

Installer System Test

The Installer System Test mode is used to test the HVAC
system(s). See Table 7. While in System Test mode,
minimum off -time for compressors is bypassed.
The Installer Test is part of Installer Setup options. Enter
Installer Setup screen and press Down arrow key to bring
up test selection(s) quickly. See Fig. 16.
Table 6. Advanced Settings Menu. (Continued)
Factory Setting
Option
Description
0
Unlocked keypad 1, 2
2
Standard
temperature
control in heating
2
Standard
temperature
control in cooling
0
No difference in
displayed
temperature and
actual room
temperature
0
No thermostat
reset.
TH8110U TOUCH SCREEN PROGRAMMABLE THERMOSTATS
Other Choices
Options
1—partially locked
keypad
2—fully locked keypad
1, 3
1—less aggressive
temperature control
(could cause
temperature
undershoot)
3—more aggressive
temperature control
(could cause
temperature overshoot)
1, 3
1—less aggressive
temperature control
(could cause
temperature
undershoot)
3—more aggressive
temperature control
(could cause
temperature overshoot)
-3, -2, -1,
°
-3
F (-1.5
0, 1, 2, 3
-2°F (-1°C)
-1°F (-.5°C)
0 F (0.°C)
1°F (.5°C)
2°F (1°C)
3°F (1.5°C)
1
Resets all Installer
Setup Options to default
values and resets
schedule to default
setting.

ADVANCED FEATURES

Outdoor or Indoor Temperature Sensor
Allow outdoor or indoor temperature sensor to absorb the
air for a minimum of five minutes before taking a reading.
See the Sensor instructions for more information.
11
Description
Unlocked—all
functions are
available.
Partially locked—
only temperature up
and down keys and
ability to enter and
modify Installer
Setup mode are
available.
Fully locked—only
ability to enter and
modify Installer
Setup mode are
available.
Applies to recovery
ramp and use of
auxiliary heat during
recovery.
Choose 1 if getting
temperature
overshoot.
Choose 3 if getting
temperature
undershoot.
Applies to recovery
ramp.
Choose 1 if getting
temperature
overshoot.
Choose 3 if getting
temperature
undershoot.
°
C)
Only calendar
settings and time are
retained.
Comments
69-1700

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents