Advanced Settings Menu Table - Honeywell TH8110U Installation Instructions Manual

Touch screen programmable thermostats
Hide thumbs Also See for TH8110U:
Table of Contents

Advertisement

TH8110U TOUCH SCREEN PROGRAMMABLE THERMOSTATS
Installer
Setup
Select
Number
Furnace Filter
0500
Change
Reminder
Humidifier Pad
0510
Replacement
Reminder
UV Lamp
0520
Replacement
Reminder
Adaptive
0530
Intelligent
Recovery™
Number of
0540
Periods
Minimum
0580
Compressor
Off Time
Heat
0600
Temperature
Range Stop
Cool
0610
Temperature
Range Stop
Clock Format
0640
Extended Fan
0650
on time Heat
Extended Fan
0660
on time Cool
69-1700
Table 6. Advanced Settings Menu.
Factory Setting
Option
Description
0
Furnace filter
change reminder
off
0
Humidifier pad
replacement
reminder off
0
UV Lamp
replacement
reminder off
1
Adaptive
Intelligent
Recovery™
control is
activated (system
starts early so
setpoint is
reached by start
of program
period).
4
Four periods
available (Wake,
Leave, Return,
Sleep)
5
Five minute
minimum off time
for compressor
90
Highest heating
setpoint.
50
Lowest cooling
setpoint.
12
12-hour clock
format
0
No extended fan
operation after
call for heat ends
0
No extended fan
operation after
call for cool ends
Other Choices
Options
Description
1-6
1—10 run time days
2—30 run time days
3—60 run time days
4—90 run time days
5—120 run time days
6—365 run time days
1-3
1—90 calendar days
2—180 calendar days
3—365 calendar days
1
1—365 calendar days
0
0—conventional
recovery (system starts
recovery at
programmed time)
2
Two periods availbable
(Wake and Sleep)
0, 2, 3, 4
Minimum number of
minutes compressor is
off between calls for
compressor
40 to 89
Temperature range (1°F
increments) of heating
setpoint.
51 to 99
Temperature range (1°F
increments) of cooling
setpoint.
24
24-hour clock format
90
Fan operation is
extended 90 seconds
after call for heat ends.
90
Fan operation is
extended 90 seconds
after call for cool ends.
10
Comments
Run time based on
call for fan.
Not shown in non-
programmable is
selected. 2 or 4
applies to all days of
the week.
Shown in 1/2 °C.
Shown in 1/2 °C.
Not shown if fan
operation is set to
fossil fuel or in Cool
Only Systems
Not shown in Heat
Only Systems.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents