Download Print this page

Advanced Menu - Honeywell R6H911RF Applications Manual

2-zone application 2x t6r smart thermostat & 2-channel receiver box

Advertisement

ADVANCED MENU

To enter the Advanced menu (installer set-up):
Press the
menu key for 5 seconds.
Menu item
Default
Language
English
OpenTherm
-
Cycle rate
6
Min on time
1 minute
Min = 5.0
Heat range
Max = 37.0
Schedule options
Daily
Opt.start on
Optimisation
Opt.stop off
Format: 24h
Time: --:--
Clock
Date: 01/09/2016
Low Load Control
ON
Temperature offset
0.0
Bind
-
Adv Reset
-
Failsafe
OFF
Special Features
Heat Range
Schedule options
Optimisation (optimal
start, optimal stop and
delayed start)
Clock setting
Low Load Control
Temperature Offset
Binding
Reset
Failsafe
Options
English, Francais, Espanol, Deutsch, Nederlands, Italiano
OpenTherm boiler data when a vailable (see OpenTherm communication)
3,6,9 or 12
1, 2, 3, 4 or 5 minutes
Min: 5.0°C to 21.0 °C, Max:21.0°C to 37.0 °C
1 = daily schedule, 2 = 5+2 days schedule
Opt start: 0 = off, 1 = on, 2 = Delayed start
Opt stop: 0 = off, 1 = on
Clock format: 1 = 12h, 2 = 24h
Setup time and date
0= Off, 1 = On
-1.5°C to 1.5 °C
Bind, check RF and clear bind.
Factory, schedule, Wi-Fi and Homekit reset
0= Off, 1 = On
Description
The normal lower temperature limit of 5
inhabitants from cold conditions. This is a useful feature aimed at supporting the elderly,
children and disabled inhabitants.
The normal upper temperature limit of 35
feature is useful for leased homes and apartments.
The thermostat has 2 default schedules: daily (every day) and 5+2 (week + weekend days)
Optimal Start: learns how long it takes your system to reach the programmed temperature. It
turns on the heating system earlier to make sure it's comfortable at the scheduled time.
Optimal Stop: Saves energy and money by switching off a little bit earlier than the normal
programmed time. If the home is up to temperature, it will not notice the effect on the
temperature, but will show a difference in the fuel bill.
Delayed start: Saves energy by slightly delaying the start of heating depending on the
difference between the scheduled temperature and the actual room temperature
Change display format (default 24hr) and adjust time and date.
When connected to Internet time and date will be synchronized
If the Receiver box is connected to an OpenTherm appliance this setting is used in the demand
control. When an appliance is no longer able to modulate lower the control switches from
modulating control to low/off control.
If the Thermostat is located in a hot/cold location and cannot be moved because of wiring then
the measured/ displayed temperature can be adjusted by +/- 1,5
homeowner wants the reading to match another appliance temperature display.
Menu to bind the Thermostat and the Receiver box, test the RF signal strength of the radio
communication and to clear an existing binding.
Menu to reset the thermostat back to factory default settings, reset the schedule to default
settings, reset the Wi-Fi and Homekit settings.
When the radio communication between the Thermostat and Receiver box is lost for longer
than 1 hour the Receiver box will start to cycle the demand 20% on / 80% off.
C can be increased up to 21
o
C can be reduced down to 21
o
8
2 ZONE T6R SMART THERMOSTAT
C to protect the
o
C to save energy. This
o
C. This feature is useful if the
o
T6R-2Z-EN0H 8603 NL01 R0718

Advertisement

loading

This manual is also suitable for: