Kenmore 318201473 Installation Instructions Manual page 5

30" gas cooktop
Table of Contents

Advertisement

Available languages

Available languages

Wall
Outlet
Location
(10_'cm)/-_
:
I
5"
,
(12.7 cm)
Recommended
,
|
area for 120V
I
|
grounded outlet
_,
/
,,
16
on rear wall.
_
(40.6 cm)
CENTRE
NOTE: If an
LINE
outlet is not
OFUNIT
available, have
I
one installed by a ,
qualified
I
technic_
..
_,
CENTRE
LINE
Figure 4'- OFUNIT
Provide
an Adequate
Gas Supply
This cooktop is designed to operate on natural gas at 4"
(10.2 cm) of manifold pressure only.
A pressure regulator is connected in series with the
manifold on the cooktop and must remain in series with
the supply line.
For proper operation,
the maximum inlet pressure to
the regulator must be no more than 14" (35.6 cm) of
water column (W.C.) pressure.
For checking the regulator, the inlet pressure must be at
least 1 "(2.5 cm) (or 2.5 kPa) greater than the regulator
manifold pressure setting. The regulator is set for 4"
(10.2 cm) of manifold pressure, the inlet pressure must
be at least 5" (12.7 cm).
The gas supply line to the appliance should be 1/2" (1.3
cm) or 3/4" (1.9 cm) pipe.
LP/Propane
Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with
natural gas.
A kit for converting to LP gas is supplied with your
cooktop. The kit is marked "FOR LP/PROPANEGAS
CONVERSION".
The conversion must be performed by a qualified service
technician in accordance with the kit instructions and all
local codes and requirements. Failure to follow
instructions could result in serious injury or property
damage. The qualified agency performing this work
assumes responsibility for the conversion.
Failure to make the appropriate
conversion can result in serious personal injury and
property damage.
Important:
Remove all packing material and
literature from cooktop before connecting gas and
electrical supply to cooktop.
Install
Pressure
Regulator
Install the pressure regulator with the arrow on the
regulator pointing up toward the unit in a position where
you can reach the access cap.
Do not make the connection too tight.
The regulator is die cast. Overtightening
may crack the
regulator resulting in a gas leak and possible fire or
explosion.
Manual
GAS
FLOW
Pressure
Shutoff
Flare
_'_
Flare
Regulator
Valve
Union
Union
_,
Nipple
Flexible
Nippl
Access
Off
Connector
Cap
All connections must be wrench-tightened
Figure 5
Assemble the flexible connector from the gas supply pipe
to the pressure regulator in the following order:
I. manual shutoff valve
2. I/2"
(1.3 cm) nipple
3. 1/2" (1.3 cm) flare union adapter
4. flexible connector
5. I/2" (1.3 cm) flare union adapter
6. 1/2" (1.3 cm) nipple
7. pressure regulator
Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If flexible
connectors
are
used, be certain connectors
are
not
kinked.
The supply line should be equipped with an approved
shutoff valve. This valve should be located in the same
room as the cooktop and should be in a location that
allows ease of
t_
opening and
closing. Do not
%%
block access to
the shutoff valve.
The valve is for
turning on or
shutting off gas
to the appliance.
Shutoff
Valve
Open position

Advertisement

Table of Contents
loading

Table of Contents