Download Print this page

Kärcher K5.690 Operator's Manual page 6

Hide thumbs Also See for K5.690:

Advertisement

Available languages

Available languages

This system is capable of producing
13800 kPa /2000 PSi to avoid rupture
and injury, do not operate this pump with
components rated less than 13800 kPa
/2000 PSI working pressure (including
but not fimited to spray guns, hose and
hose connections).
Before servicing, cleaning or removing
any part& shut off power and refieve
pressure.
This product must be grounded. If it
should malfunction or breakdown,
grounding provides a path of least resis-
tance for electric current to reduce the
risk of electric shock. This product is
equipped with a cord having an equip-
ment-grounding conductor and a
grounding plug. The plug must be
plugged into an appropriate outlet that is
properly installed and grounded in ac-
cordance with all local codes and ordi-
nances.
A_ DANGER
Improper connection of the equipment-
grounding conductor can result in a risk
of electrocution.
Check with a qualified
electrician or service personnel if you
are in doubt as to whether the outlet is
properly grounded. Do not modify the
plug provided with the product - if it will
not fit the outlet, have a proper outlet in-
stalled by a quafified electrician. Do not
use any type of adapter with this prod-
uct.
This pressure washer is provided with a
ground-fault circuit-interrupter
(GFCI)
built into the plug of the power-supply
cord. This device provides additional
protection from the risk of electric shock.
Should replacement of the plug or cord
become necessary, use only identical
replacement parts that include GFCl
protection.
AX CAUTION
When connecting the water inlet to the
water supply mains, local regulations of
your water company must be observed.
In some areas the unit must not be con-
nected directly to the public drinking wa-
ter supply. This is to ensure that there is
no feedback of chemicals into the water
supply. Direct connection via a receiver
tank or backflow preventer, for example,
is permitted.
Dirt in the feed water will damage the
un#. To avoid this risk, we recommend
fitting a water filter.
Garden hose must be at least 1/2
inch or 5/8 inch in diameter.
Flow rate of water supply must not
fall below 2 GPM (gallons per min-
ute).
Flow rate can be determined by run-
ning the water for one minute into an
empty 5-gallon container.
The water supply temperature
must
not exceed 104°F/40°C.
Never use the pressure washer to
draw in water contaminated with sol-
vents, e.g. paint thinners, gasoline,
oil, etc.
Always prevent debris from being
drawn into the unit by using a clean
water source.
SAVE THESE
INSTRUCTIONS!
6 English

Advertisement

loading