Installation
Instructions
(cont'd)
Temperature-Pressure
Relief Valve
_,WARNING
At the time of manufacture this water heater was provided
with a combination temperature-pressures reliefvalvecertified
by a nationallyrecognized testinglaboratory that maintains
mriodic inspection of production of listedequipmentor mate-
rials, as meeting the requirements for Relief Valvesand
AutomaticGasShutoffDevices for Hot Water Supply Systems,
and the latest edition of ANSI Z21.22 and the code require-
mentsof ASMF. If replaced, t he va_e must meet the reqube-
ments of localcodes, b ut not lessthana combination tempera-
ture and pressure relief valvecertifiedas meetingthe require-
mentsfor ReliefVabesandAutomaticGasShutoffDevices for
Hot Water Supply Systems, ANSI Z21.22bya naU.onally recog-
nized testing laboratorythat maintains periodic mspec_an of
production oflistedequipmentor materi_
The valvemustbe markedwith a maximumset pressure not
to exceed the marked bydrostatic workingpressureof the
water heater (150 Ibsdso e in.) and a discharge c apacity not less
than the wnter hEnterinputrate as shEwn on thEmodel reting
plate. (Electricheaters- watts dividedby 1000 x 3415 equal
BTU/Hr.rate.)
Yourlocaljurisdictional authority, w hilemandating the useof a
temperature-pressore reliefvalvecomplying with ANSI 7.21.22
and ASNE, may requirea valvemodeldifferentfrom the one
fomisbedwiththe water heater,
Compliance with such_
requirements mustbe satlsEed by
the installeror end userof the v_ter heaterwith a locallyp.re-
scribed temperature-pressure relief valveinstalled in the desig-
nated opening in the water heater in placeof the factoryfur-
nished valve.
Forsafeoperationof the waterheater,the railefvalvemustnot
be removedfrom it'sdesignated opening or plugged.
The temperature-pressure re||el v_e, mustbe inst_ed directly
intothe fittingof the waterheaterde_gnated for the reliefvalve.
Position the valvedownward and provide tubingsothat anydis-
chargewill exit onlywithin 6 inchesabove,or at any distance
belowthe structuralfloor.Be certainthat no contactis made
with anyllveelectrical p art.The discharge o pening mustnot be
blocked or reduced in sizeunderanycircumstance_ Excessive
length, ever30 feet,or useof morethan fourelbows cancause
restriction andreduce the discharge c apacity of thevalve.
No valveor otherobstruction isto be placedbetween the relief
v_ve andthE tank.Do net connecttubingdirectly te dlscherge
drainunless a 6" air gapisprovided. Toprevent b odily injury, h az-
ard to life,or propertydamage, t he relief valvemustbe allowed
to discharge w ater in quantities should circumstances demand. I f
the discharge p ipeisnot connected to a drainor othersuitable
means, t he water flowmaycause propertydamage.
The Discharge Pipe:
• Must not be smallerin sizethan the outlet pipesize of the
valve, o r haveanyreducing couplings o r other restHction_
• Mustnot beplugged or blocl_l.
• Mustbe of materiallistedfor hot waterdistribution.
• Must be installedso as to allowcompletedrainageof both
the temperature-pressure relief valve, and the discharge
pipe.
• Mustterminate at an adequatedrain.
• Mustnnt haveanyvalvebetwean the relief valveandtank.
AWARNING
ThE temperature-pressure relief valve must be manually
operated at leastonce a year. Caution shouldbe taken to
ensureth=e(I) no one is in front of or aroundthe ontle'd: of
the temperature-pressure relief valvedischarge line, and (2)
the water manually dischargedwill not causeany bodily
injury or property damage because the water may be
extremely h ot.
If after manually operatingthe valve, it feJlsto completely
reset and continues to releasewater, immediatelyclosethe
cold water inlet to the water heater, follow the draining
blatructiens,and replace the tempera|ore-pressure retief
valvewith a new one_
HOT
SHUT OFF
VALVE
COLD
PRESSURE
RELIEF VALVE
DISCHARGE
PIPE (Do not
or plug)
FLOOR DRAIN
RELIEFVALVEOPENING
At the timeof manufacture, thiswaterheaterwasprovidedwitha combination tem-
peratu_re
relief valve listedas complying with the slandard for rdief valves
andautomatic g as|hut-off devices f or hot water supply systems, ANSI7.21_2.For
safe opera, o nof the wa_er _er,
the _
_ve re.st not be removed f rom_ des-
ignated p ointofinstalla_on or plugged.
Yourlocal j urisdic_onal authori_, w hilemandating the useof a temperatur_pressure
reliefvaJve c omplying withANSIZ21.22and ASME_ m ayr_quirea valve model d iffer-
er_fromd_ o_efur_fl_ed_h thev_,.erhe_er.
Compliance withsuch localrequirements mustbes_tisfied b ytheins_leror enduser
of the water heaterwith a locallyprescribed temperature-pressure nllief valve
Installed i nthe dasil_atec[ opening I n_ waterheater
See manual h e_ling -'1_.mpe_tur_-Pre_sure Retief V alves" for In_llatio_ andmaint_
nance of reliofva_, discharge line,andother_y
I_-,cau_ons.