: Nov. 15 2006
4
5)
Loosen the blue screw.
6)
Turn the blue screw (A) counterclockwise. Check to insure that
the lock is released as shown with (B), and pull out the primary
transfer unit toward you.
* If this procedure is not executed, the intermediate transfer
belt may be damaged.
7)
Remove the transfer belt protect sheet horizontally in the arrow
direction.
D. Applying titanium hydroxide
4
1)
B
A
2)
3)
MX-3500N/4500N, MX-3501N/4501N 1 – 5
Remove the cleaner unit.
* Since titanium hydroxide is of fine powder, it may disperse
when removing from the bag. To prevent against dispersion,
remove it from the bag at a lower position.
* Pushing the bag lightly against the belt provides sufficient
application of titanium hydroxide. Lift the bag from the appli-
cation surface by 5 mm or less.
* Apply titanium hydroxide before installing the cleaner unit.
Install the primary transfer UN with its backside facing upward
and remove the cleaner frame UN.
Apply titanium hydroxide to the belt within approx. 15 cm from
the driving roller.
15cm