Menu #2 - Avital AviStart 3200 Installation Manual

Table of Contents

Advertisement

I The 30-second timed output selection will latch the Channel 2 output on for 30 seconds when the remote
button is pressed or until the button is pressed again within the 30 seconds.
I A second unlock output will provide a second unlock pulse whenever the unlock button is pressed within 15
seconds after unlocking the system. This setting could be used to unlock the passenger doors when installing
progressive door locks, for instance.
NOTE: Programming Channel 2 for second unlock will link the RED/WHITE wire to the unlock button. Pressing
the unlock button once will send the output to the H4/A or H4/C unlock output. Pressing the unlock
button a second time within 15 seconds will send a negative (-) unlock pulse to the RED/WHITE wire.
1-8 FACTORY ALARM DISARM WITH CHANNEL TWO: Any time Channel 2 is activated from the remote transmit-
ter the factory disarm output will pulse to disarm the vehicle's factory anti-theft device. This option can be
programmed off if desired.
1-9 STEALTH CODE-HOPPING ON/OFF: The system features Stealth Code-Hopping as an option. To use Stealth
Code-Hopping technology, this feature must be programmed on.

menu #2

2-1 ENGINE CHECK ON/OFF: In the default setting the remote start will monitor either the vehicle's tach wire or
voltage depending on the programming of Feature 2-2. If programmed off, the vehicle will crank for the pro-
grammed crank time (Feature 2-5) and will not verify with tach or voltage that the vehicle is running. In the off
setting, if the vehicle fails to start, the ignition can stay on for the entire run duration. Using tach or voltage
check is always recommended if possible.
2-2 TACH WIRE SENSE/VOLTAGE SENSE: If the tachometer signal wire is used, this feature must be left in the
default (tach wire connected) setting. If programmed to the voltage sense setting, the unit will crank the starter
for a preset time that can be programmed in Feature 2-5. Once the starter has been engaged, the system will
check the voltage level to verify the engine is running. The threshold for the voltage level test can be programmed in
Feature 2-6. When using voltage sense mode, connecting the H3/5 VIOLET/WHITE tachometer input is not necessary.
2-3 RUN TIME 12/24/60 MINUTES: This feature controls how long the engine will run before it "times
out" and shuts down. Programmed to the default setting the engine will run for 12 minutes. If the 24-
minute run time is desired, change this feature to the on-board LED off setting.
2-4 PARKING LIGHTS FLASHING/CONSTANT: In the default setting, the unit will flash the vehicle's parking lights
while remote started. The constant setting will turn the parking lights on solidly for the entire run duration.
2-5 CRANK TIME 0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0: If Feature 2-2 is programmed to the voltage sense
setting, the crank time must be set to the appropriate duration. The default setting is 0.6 second. If a different
crank time is desired, select Feature 2-5 and (while pressing the Valet®/Program switch) advance to the next time
by pressing the Channel 2 button. The unit will flash the LED to indicate which time is selected. Once the 4.0
second setting is reached the next press of Channel 2 will reset the system to the shortest setting.
36
© 2000 Directed Electronics, Inc. Vista, CA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents