Initializing the Internal Memory

Execute the following procedure when you return the internal
memory settings to their factory set state (initialize the internal
memory), such as when the amplifier has been moved to a dif-
ferent location.
1. Turn off the power.
2. Set device setup DIP switch 7 to the down-
ward position and switch 8 to the upward
position.
3. Turn on the power. The initializing operation
will start.
• In the case of the XMV8280/XMV8140
During initialization, the [NETWORK], [YDIF], and
[PANEL LOCK] indicators will flash. When initialization
is complete, the [NETWORK] and [YDIF] indicators will
flash.
• In the case of the XMV8280-D/XMV8140-D
During initialization, the [PRIMARY], [SECONDARY],
[SYNC] (green), [SYNC] (orange) and [PANEL LOCK]
indicators will flash. When initialization is complete, the
[PRIMARY], [SECONDARY] and [SYNC] (green) indi-
cators will flash.
If the unit fails to initialize, the [POWER] indicator will
light, the [ALERT] indicator will flash, and other indica-
tors will turn off. Please contact your Yamaha dealer.
4. Make sure the initializing operation is com-
plete and turn off the power.
5. Set device setup DIP switches 7 and 8 to the
upward position (RESUME).
6. Turn on the power.
The following parameters held in memory are initialized.
• Attenuator values
• Polarity settings
• HPF settings
• Analog/digital input setting
• [SIGNAL] indicator display setting
• Event log
* When the unit is shipped from the factory, the device setup
DIP switches are all in the upward position.