Electrical Connection (3-wire)
(cont.)
Bare Wire Connection
Eyelet Connection
1
1
To make a bare wire connection, use holes on the left
side of the terminal block. To connect eyelet style
leads to outside terminal. Attach neutral wire (white)
wires, use holes on right side of terminal.
5
1
Push supply cord toward terminal
block to relieve strain, reattach supply cord strain relief
bracket over supply cord.
16
4
1
Attach line #1 (red) and line #2 (black)
to center terminal on the terminal block.
6
Reattach access door.
Electrical Connection (4-wire)
WARNING
To avoid risk or electrical
shock, personal injury or death;
grounding product to the frame of the unit
may or may not be permitted through
your local codes. If ground to the frame is
not permitted then a 4-conductor power
cord must be used.
Use a 4-wire power supply cord kit rated for
40 amps – 125/250 volts with closed loop
terminals and marked for use with ranges.
Where local codes do not permit grounding
through neutral, use a 4-wire power supply
cord. The cord or conduit must be secured
to the range with the strain relief bracket.
The electrical connection is made at the
terminal block, which is located behind the
access door on the back of the range.
2
3
Remove supply cord strain relief
bracket and three supply cord mounting screws on
the terminal block.
17
WARNING
To avoid risk of electrical shock,
personal injury or death; verify
your appliance has been properly
grounded in accordance with local codes
or in absence of codes, with the National
Electrical Code (NEC) ANSI/NFPA-70 –
latest edition.
1
Remove access door.
3
2
Remove grounding screw. Cut-off
and discard ground strap.