Clearance Dimensions (Proximity To Cabinets); Clearance Dimensions (Wood/Composite Overlay) - Viking RVDR3305BSS Installation Manual

Freestanding 30” dual fuel self-clean sealed burner range
Hide thumbs Also See for RVDR3305BSS:
Table of Contents

Advertisement

Clearance Dimensions
• This range may be installed directly
• Wall cabinets above the range must be a
adjacent to existing 36" (91.4 cm) high
base cabinets.
IMPORTANT: The side trim MUST be
3/8" (.95 cm) above the adjacent base
cabinet countertop. This can be
accomplished by raising the unit using
the adjustment spindles on the legs.
• The range CANNOT be installed
directly adjacent to sidewalls, tall
cabinets, tall appliances, or other
side vertical surfaces above
36" (91.4 cm) high. There must be
a minimum of 6" (15.2 cm) side
clearance from the range to such
combustible surfaces above the
36" (91.4 cm) counter height.
• Within the 6" (15.2 cm) side
clearance to combustible vertical
surfaces above 36" (91.4 cm), the
maximum wall cabinet depth
must be 13" (33.0 cm) and wall
"
3 6
)
cabinets within this 6" (15.2 cm)
c m
. 4
9 1
(
side clearance must be
18" (45.7 cm) above the
36" (91.4 cm) high countertop.
CAUTION
To avoid risk of personal injury;
the use of cabinets for storage
above the appliance may result
in a potential burn hazard. Combustible
Note: This range ships standard with a backguard.
items may ignite, metallic items may
Minimum clearance for back wall is 0" with
become hot and cause burns. If cabinet
backguard or high-shelf.
storage is used, the risk can be reduced by
Note: If a range hood is installed, wall cabinets
installing a rangehood that projects
above the range have a different minimum
horizontally a minimum 5" (12.7 cm)
clearance height.
beyond the bottom of cabinets.
8
(Proximity to Cabinets)
minimum of 42" (106.7 cm) above the
range cooking surface for the full width
of the range. This minimum height
requirement does not apply if a range
hood is installed over the cooking surface.
2 9
- 7 /
( 7 5
8 "
. 9
c m
.
a x
)
" m
)
1 3
c m
. 0
3 3
(
i n .
" m
)
c m
4 2
6 . 7
6 "
( 1 0
m i
( 1 5
n .
. 2
c m
)
i n .
" m
)
c m
1 8
. 7
( 4 5
"
3 / 8
)
c m
9 5
( 0 .
A
Range
"A"
Width
Dimension
30"
30" (76.2 cm)
Clearance Dimensions
The bottom of a standard hood should be
W o
30" (76.2 cm) min. to 36" (91.4 cm) max.
above the countertop. This would typically
result in the bottom of the hood being
66" (167.6 cm) to 72" (182.9 cm) above the
floor. Refer to the range hood installation
instructions for additional information. These
dimensions provide for safe and efficient
operation of the hood.
6 6
" m
( 1 6
i n .
7 . 6
c m
t o
7 2
Note: Minimum clearance
" m
( 1 8
a x
for back wall is 0" with
2 . 9
c m
backguard or high-shelf.
W o
o d
/ C o
m p
O v
o s i
e r l
t e
a y
Wall Installation
"
3 0
)
c m
3 0
6 6
. 2
" m
" m
( 7 6
( 1 6
( 7 6
i n .
i n .
. 2
7 . 6
c m
c m
t o
)
3 6
t o
7 2
)
6 "
m )
" m
" m
. 2 c
( 9 1
( 1 8
a x
a x
( 1 5
. 4
.
2 . 9
.
c m
c m
)
)
Island Installation
9
(Wood/Composite Overlay)
o d
/ C o
m p
O v
o s i
e r l
t e
a y
"
2 4
)
c m
. 0
( 6 1
o r
"
2 7
)
c m
3 0
)
. 6
( 3 8
" m
0 "
( 7 6
i n .
m )
. 2
.
0 c
c m
(
t o
)
3 6
)
" m
( 9 1
a x
. 4
.
c m
)
Important: If installing with an accessory
island trim, there must be a minimum of
6" (15.2 cm) clearance from rear of range
to a combustible wall.
Note: Clearances from non-combustible
materials are not part of the ANSI Z21.1
scope and are not certified by CSA.
Clearances to non-combustible materials
must be approved by the authority having
jurisdiction.