Sony VPL-DX126 VPL-DW126 Operating Instructions Manual page 46

Product manual (vpl-dx146 dw126 operation manual)
Hide thumbs Also See for VPL-DX126 VPL-DW126:
Table of Contents

Advertisement

Caution
Do not put your hands into the lamp
replacement slot, and do not allow any
liquid or other objects into the slot to avoid
electrical shock or fire.
4
Insert the new lamp all the way in until
it is securely in place (1). Tighten the
two screws (2). Fold down the handle
to replace it (3).
Fold down the handle.
3
Notes
• Be careful not to touch the glass surface
of the lamp and a inside conductor.
• Insert the handle firmly to attach it
securely.
• The power will not turn on if the lamp is
not secured properly.
5
Close the lamp cover and tighten the
1 screw.
46
Replacing the Lamp
1
2
2
6
Connect the AC power cord to a wall
outlet and turn on the projector.
7
Reset the lamp timer for
the next replacement time.
Select "Lamp Timer Reset" on the
Function menu then press the ENTER
key. When a message appears, select
"Yes" to reset the lamp timer (page 23).
Caution
Disposal of the used lamp
For the customers in the USA
Lamp in this product contains mercury.
Disposal of these materials may be
regulated due to environmental
considerations. For disposal or
recycling information, please contact
your local authorities or the
Telecommunications Industry
Association (www.eiae.org).
notification of