Checking And Updating Firmware /Bootbios - Fujitsu PRIMERGY 4Gbit/s FC I/O Modules Owner's Manual

Primergy 4gbit/s fc i/o modules
Table of Contents

Advertisement

4.3
Checking and Updating Firmware /
BootBIOS
There are two methods to check and update Firmware/BootBIOS. The results will bring no
difference.
"4.3.1 Using LightPulse Utility / NT"(pg.58)
"4.3.2 Using HBAnyware Utility"(pg.60)
4.3.1
Using LightPulse Utility / NT
This product name displayed in LightPulse Utility/NT is "Adapter * - BX600-FC42E * Port *".
1
Click the "Start" button
"Emulex"
2
Select "Firmware Maintenance" in the "Category" field.
For PG-FCD201, Adapter 0 and 1 are displayed.
3
For the firmware version, check the "Revision" value in "Functional
Firmware".
• When the version is "2.70x6", proceed to Step 7.
• When the version is other than "2.70x6", proceed to Step 4.
4
Click [Download].
Although the warning window appears, click [OK].
5
Insert the driver disk (CD-ROM) into the CD-ROM drive, select the
Firmware file in the CD-ROM drive, and click [Open].
Firmware update starts.
6
Check the "Revision" value in "Functional Firmware" is "2.70x6".
58
"lpUtilNT" in this order.
[CD-ROM drive]:\FirmBIOS\zf2.70x6.all
"Programs" or "All Programs"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primergy pg-fcd201

Table of Contents