How To Execute Mcu Code - Samsung 920NW - SyncMaster - 19" LCD Monitor Service Manual

19" lcd monitor
Hide thumbs Also See for 920NW - SyncMaster - 19" LCD Monitor:
Table of Contents

Advertisement

3-5 How to execute MCU Code

3 Alignments and Adjustments
6. Write DDC ok.
1. Set the options.
-. Manufacture: MSTAR
-. Device Type: TSUM16_ROM128K_ext_flash
-. Communication Port: DSUB15 (Analog)
-. External Memory: PM25LV010E
2. Click 'Connect File' button, and select the
MCU code.
3. Click 'Read File' button, and select the MCU
code.
3-5