Require Output Sequence

When an output sequence is Required, all output data must conform to an
edited sequence or the scanner will not transmit the output data to the host
device. When it's On/Not Required, the scanner will attempt to get the
output data to conform to an edited sequence but, if it cannot, the scanner
transmits all output data to the host device as is.
When the output sequence is Off , the bar code data is output to the host as
the scanner decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Required

Multiple Symbols

When this programming selection is turned On, it allows you to read multiple
symbols with a single pull of the scanner's trigger. If you press and hold the trig-
ger, aiming the scanner at a series of symbols, it reads unique symbols once,
beeping (if turned on) for each read. The scanner attempts to find and decode
new symbols as long as the trigger is pulled. When this programming selection
is turned Off, the scanner will only read the symbol closest to the aiming beam.
Default = Off.
On
4 - 26
*Off
On/Not Required
* Off