Warning System

Warning Description Tables

If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the
WARNING lamp, lamps on the LCD monitor and a warning tone.
Warnings have priorities. If multiple errors occur simultaneously, the WARNING lamp, warning display on the screen, and
alarm tone are displayed in order of priority shown in the table below.
Warning
Priority
LCD indication
type
SYSTEM ERROR cause
1
System error
indication
2
*
Incorrect
TURN POWER OFF
2
P2 card
Blinks red
removal
LOW BATTERY blinks
red, and the battery level
The
bar blinks with the empty
3
battery is
status. (This indication
exhauseted
appears even if CARD/
BATT is set to OFF in the
DISPLAY SETUP screen.)
VERSION MISMATCH
Version
4
PLEASE UPDATE
mismatch
Blinks white
High
Temperature
HIGH TEMPERATURE
5
error
Blinks red
detectionl
FAN STOPPED cause
6
Fan stop
indication
3
*
When the alarm sounds, audio is not output to the camera speakers or earphones. The DISP/MODE CHK button
1
*
cancels only the alarm tone when pressed during an alarm.
P2 SYSTEM ERROR cause indication
2
*
• P2 MICON ERROR: The P2 microprocessor does not respond.
• P2 CONTROL ERROR: A P2 recording control error has occurred.
• CAM MICON ERROR: The camera microprocessor does not respond.
• P2 MICON LINK ERROR: A connection error between P2 microprocessors has occurred.
FAN STOPPED cause indication
3
*
• FAN: FAN error position (1, 1/2, 1/3, 2, 2/3, 3, 1/2/3)
WARNING
Tally lamp
Blinks 4
Blinks 4
times per
times per
blinks red.
second
second
Blinks 4
Blinks 4
times per
times per
second
second
Blinks 1 time
Lights
per second
Blinks 4
Blinks 4
times per
times per
second
second
Off
Off
Off
Off
blinks red
Warning description
Alarm
and recording/playback
lamp
tone
*
1
Reference signal or
Continuous
communication error.
tone
Operation stops.
A P2 card was removed
during access and card data
Continuous
was corrupted.
tone
Both P2 card access LEDs
blink in orange. Recording/
playback cannot start.
The battery is exhausted.
Recording and playback
Continuous
stop. The camera stops
tone
automatically when the
voltage drops.
Version misatch has occurred.
Only SD CARD FORMAT and
No
UPDATE are available with the
thumbnail menu.
High temperature error
is detected. Operation
No
continues, but abnormal
recording/playback may
occur.
The fan is in failure and has
stopped. Although operation
continues with the fan
No
stopped, it may raise the
temperature inside the unit,
causing abnormal recording/
playback.
Countermeasures
operation
Check the cause
indication
*
and consult your
distributor.
Turn off the power.
Repair the P2 card if
the clips on the card
are corrupted.
Replace the battery.
Perform CARD
UPDATE.
Stop operation
immediately
and consult your
distributor.
Check the cause
indication
*
consult your
distributor.
(Continued on the next page)
2
and
3
1