WIRING CONFIGURATION
The Lighting Module is wired directly to the lighting circuit and can be controlled by one
or more Remote switches producing three, four, or five-way circuits. Multiple-way
circuits make it possible for a group of switches to control the same set of lights. This
section will illustrate how to hook-up the connections.
Configuration Definitions:
SERVICE PANEL - Source of electricity providing the Line and Neutral
REMOTE SWITCH - One or more remote switches controlling the light circuit via the
Lighting Module control inputs.
Wiring Notes:
a. Remote switches require a Line Voltage input (Black) that is always hot. Do not
connect to the load (switched) circuit.
b. The gray wire on the Remote Switch only serves to light the red LED, which
provides as a night light and power indicator. It does not indicate the state of t he
load. This wire can be tied to neutral or earth ground.
Lighting Module
(Yellow)
(Black)
(Gray)
Gnd*
Gnd*
Remote 1
Remote 2
* Can be connected to Nuetral
Wiring Diagram
Page 3
Ground
Gnd*
Gnd*
Remote 3
Remote 4
Line
Neutral
Remote
Switches
(Optional)