Download Print this page

Whirlpool RH8930XLS Installation Instructions Manual page 2

Vented kitchen range hood for 120 v. operation

Advertisement

TRAIN
CAP
1. Make a template or transfer measurements shown in Fig. 3
to cabinets or wall.
2. Cut holes to accomodate
ventilating
duct allowing W' (.6
cm) clearance on all four sides for back vent. Allow J/4" (1.9
cm) clearance toward front for vertical vent. Allow %" (.6 cm)
on other three sides for top vent.
3. Cut appropriate
hole for electrical wiring.
4. Run wire through wall or cabinets according to National
Electrical
Code and Applicable
local codes. (DO NOT turn
power on until installation
is complete.)
5. Remove blower housing and filters for easier installation.
See exhaust unit assembly illustration
on page 6.
6. Remove screw holding junction box cover.
7. Remove proper electrical
knockout. See Figure 3.
8. Remove proper venting knockout. See Figure3. NOTE: If
horizontal
discharge
is selected an additional
knockout
in
the blower cradle must be removed.
9. Attach
the damper
as shown in Figure 5 for vertical
discharge or Fig. 6 for horizontal
discharge.
10. Lift the hood into position. Mark location of four mounting
holes.
11. Remove hood and start all four screws in center of
narrow neck of keyhole slot marked on cabinet bottom.
12. Lift the hood into position simultaneously
feeding the
electrical wire through the knockout. Follow applicable
local
codes and/or latest National
Electrical
Code for electrical
connector
to be used at field wiring entrance.
13. Tighten screws to secure hood. Be sure screw head is in
narrow neck of keyhole slot.
14. Install proper duct work. See page 4
15. Complete
electrical wiring in junction
box according
to
the National
Electrical
Code and applicable
Local Codes
NOTE:
This
unit
must
be
permanently
grounded
in
accordance
with the National Electrical Code and applicable
Local codes.
16. Replace junction
box cover.
17. Replace
blower.
Note different
blower
positions
in
Figure 5 for vertical
venting
and Figure 6 for horizontal
venting. See Page 3 for correct blower installation.
18. Replace blower cover, light frame assembly and filters.
NOTE: It has been found that a large part of the energy loss
of the average home is due to outside air infiltrating
the
structure.
Seal around ductwork
where it passes through
outside walls or ceiling. Seal around electrical wiring also.
19. Be sure that damper which is supplied with this model is
properly
installed. (See Figures 1 8 2).
6-1
FIG&E
5
IF RAIN
CAP
HAS
A CAMPER,
REMOVE
DAMPEF)
BLADE
FROM
rCOO0
FIGURE 1
VERTICAL
VENTING
,a
3%.
x IO"
RECTANGULAR
IF RAIN
CAP HAS
A DAMPER.
REMOVE
DAMPER
BLAOE
FROM
HOOD.
FIGURE 2
HORIZONTAL
VENTING
c5mf
FIGURE 6
FIGURE 4
Page 2

Advertisement

loading