York TCGD12 S21S2H Technical Manual

York TCGD12 S21S2H Technical Manual

Split-system air conditioners 13 seer – r-22

Advertisement

TECHNICAL GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
13 SEER – R-22
MODELS:
TCGD12 THRU 60
(1 THRU 5 NOMINAL TONS, 1 PHASE)
LISTED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System

DESCRIPTION

The 13 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG's complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-On coils are available for use
with upflow, downflow, or horizontal furnaces and air han-
dlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
5-year limited compressor warranty.

FEATURES

• QUALITY CONDENSER COILS - The coil is constructed
of aluminum microchannel tubing and enhanced aluminum
fins for increased efficiency and corrosion protection.
• PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, and a single panel covering the electrical con-
trols make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
400034-YTG-B-0708

Advertisement

Table of Contents
loading

Summary of Contents for York TCGD12 S21S2H

  • Page 1 Certified in accordance with the Unitary Small Equipment cer- tification program, which is based on ARI Standard 210/240. Visit us on the web at www.york.com Additional rating information can be found at www.ahridirectory.org FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE...
  • Page 2 400034-YTG-B-0708 Physical and Electrical Data TCGD12 TCGD18 TCGD24 TCGD30 TCGD36 TCGD42 TCGD48 TCGD60 MODEL S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2 Unit Supply Voltage 208-230V, 1φ, 60Hz 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 11.3 14.0 18.2 19.9...
  • Page 3 400034-YTG-B-0708 Additional R-22 Charge / Orifice Size for Various Matched Systems TCGD12 TCGD18 TCGD24 TCGD30 TCGD36 TCGD42 TCGD48 TCGD60 Outdoor Unit S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2 0.041 / 2A 0.052 / 2A 0.059 / 0.061 / 2A 0.065 / 2A...
  • Page 4 400034-YTG-B-0708 Additional R-22 Charge / Orifice Size for Various Matched Systems (Continued) TCGD12 TCGD18 TCGD24 TCGD30 TCGD36 TCGD42 TCGD48 TCGD60 Outdoor Unit S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2(H) S21S2 0.041 / 2A 0.052 / 2A 0.059 / 0.061 / 2A 0.065 / 2A...
  • Page 5 400034-YTG-B-0708 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING COIL UNIT NET MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER AC WITH MA MA08B FC/MC18B 18.0 12.6 13.00 11.00 TCGD18S21S2(H) MA08B FC/MC24B 18.0 12.6 13.00 11.00 MA08B FC/MC35B 24.0...
  • Page 6 400034-YTG-B-0708 COOLING CAPACITY - With Air Handler Coils (Continued) AIR HANDLER COOLING COIL UNIT NET MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER AC WITH AHP / SHP / F*FP TCGD12S21S2(H) AHP18 – 12.0 13.00 11.00 AHP18 – 18.0 12.6 13.00...
  • Page 7 400034-YTG-B-0708 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** COOLING COIL NET MBH UNIT MODEL CFM RANGE RATED MODEL SEER (Min.-max.) TOTAL SENS. 450 - 750 14,17 FC/MC/PC18 12.0 13.00 11.00 TCGD12S21S2(H) 450 - 750 HC18 12.0 13.00 11.00 450 - 750...
  • Page 8 400034-YTG-B-0708 COOLING CAPACITY - With Variable Speed Furnaces COOLING VARIABLE SPEED COIL UNIT MODEL Net MBH RATED FURNACE MODEL MODEL SEER TOTAL SENS. 13 SEER AC WITH VARIABLE SPEED FURNACES PV8*A12 FC/MC/PC18A 18.0 13.0 14.00 12.00 PV9*A12 FC/MC/PC18A 18.0 12.9 14.00 12.00 P(C,V)9*B12...
  • Page 9 400034-YTG-B-0708 COOLING CAPACITY - With Variable Speed Furnaces (Continued) COOLING VARIABLE SPEED COIL UNIT MODEL Net MBH RATED FURNACE MODEL MODEL SEER TOTAL SENS. 13 SEER AC WITH VARIABLE SPEED FURNACES PV8*A12 FC/MC/PC37A 1200 35.2 25.0 14.00 12.00 PV9*A12 FC/MC/PC37A 1200 35.2 25.0...
  • Page 10 400034-YTG-B-0708 ACCESSORIES 1H/1C, manual changeover electronic non-programmable thermostat. Refer to Price Manual for specific model numbers. 1H/1C, auto/manual changeover, electronic programmable, HARD START KIT - Required when using TXV indoor coil. deluxe 7-day, thermostat. Also, provides increased starting torque for areas with low 1H/1C, auto/manual changeover, electronic programmable.
  • Page 11 400034-YTG-B-0708 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD12S21S2(H) INDOOR COIL MODEL NO. FC/MC/PC18 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 11.3 11.9 12.1 13.1 14.1 11.7 12.4 12.3 13.2 14.1 12.1 12.9 12.6 13.2 14.1 S.C.
  • Page 12 400034-YTG-B-0708 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD18S21S2(H) INDOOR COIL MODEL NO. FC/MC/PC18 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 15.4 17.1 16.7 18.1 18.0 16.2 17.6 17.2 18.2 18.0 17.0 18.2 17.6 18.3 18.0 S.C.
  • Page 13 400034-YTG-B-0708 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD24S21S2(H) INDOOR COIL MODEL NO. FC/MC/PC36 IDCFM 1000 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 21.5 24.0 23.5 25.4 26.2 22.7 24.9 24.2 25.8 26.4 23.9 25.8 24.9 26.2 26.7 S.C.
  • Page 14 400034-YTG-B-0708 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD30S21S2(H) INDOOR COIL MODEL NO. FC/MC/PC35 IDCFM 1000 1200 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 27.8 29.9 29.6 30.6 31.8 29.2 30.1 29.7 30.8 31.8 30.6 30.4 29.8 31.1 31.8 S.C.
  • Page 15 400034-YTG-B-0708 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD36S21S2(H) INDOOR COIL MODEL NO. FC/MC/PC43 IDCFM 1000 1200 1400 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 35.6 36.1 34.4 37.6 38.5 37.2 37.4 35.5 38.5 38.9 38.9 38.6 36.7 39.4 39.2 S.C.
  • Page 16 400034-YTG-B-0708 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD42S21S2(H) INDOOR COIL MODEL NO. FC/MC/PC43 IDCFM 1200 1400 1600 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 39.7 42.3 41.6 45.1 46.3 41.4 43.5 42.3 45.7 46.7 43.1 44.7 43.0 46.2 47.0 S.C.
  • Page 17 400034-YTG-B-0708 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD48S21S2(H) INDOOR COIL MODEL NO. FC/MC/PC48 IDCFM 1400 1600 1800 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 48.0 48.3 46.7 49.9 49.6 49.2 49.1 47.2 50.1 50.1 50.3 49.9 47.6 50.4 50.6 S.C.
  • Page 18 FC/MC62D 0.98 1.01 0.98 P(C,V)9*D20 FC/MC62D 1.00 1.02 1.00 Subject to change without notice. Printed in U.S.A. 400034-YTG-B-0708 Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: 400034-YTG-A-0408 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069...

Table of Contents