tions in timber framed and light steel framed buildings".
Please note the safety instructions below before deciding
where to install the boiler:
a
Caution!
Do not install the appliance in rooms prone to
frost. In rooms with aggressive steam or dust,
the appliance must be operated independent of
the ambient air.
When choosing the place of installation and while operating the
appliance, make sure that the air supply is free of chemical
substances containing fluorine, chlorine, sulphur etc. Sprays,
solvents and cleaning agents, paints, adhesives etc. contain the
kind of substances that can lead to corrosion even in the ex-
haust system when the appliance is operated depending on the
ambient air in the worst case scenario. Particularly in hair-cut-
ting salons, lacquering and finishing, cleaning facilities, the ap-
pliance must be operated independent of the ambient air! Oth-
erwise, a separate installation room is required to guarantee
that the air supply is free of the above mentioned substances.
3.4

Gas supply

The gas supplier should ensure the availability of an ade-
quate supply of gas. A gas meter may only be connected
to the service pipe by the supplier of gas or their contrac-
tor. An existing meter should be checked to ensure that it
is capable of passing the rate of gas supply required. In-
stallation pipes should be fitted in accordance with BS
6891. In IE the current edition of IS 813. Pipe work from
the meter to the boiler must be of an adequate size. Do
not use pipes of a smaller size than the boiler gas con-
nection (15 mm). The complete installation must be
checked for leaks and purged as described in BS 6891.
d
Danger!
Vaillant appliances are certified only for use
with genuine Vaillant flue pipes. Only use genu-
ine Vaillant flue pipes. Malfunctions can occur if
you use other accessories. These may result in
damage and injury. You will find a list of genu-
ine flue pipes in the Vaillant installation manual
for flue pipes. The CE mark is valid only if the
appliance is operated with Vaillant flue pipes.
3.5

Flue options

There are various flue systems to choose from, as follows:
60/100 standard horizontal air/flue duct, see fig 3.1.
60/100 telescopic horizontal air/flue duct, see fig 3.2.
60/100 Vertical air/flue duct and terminal, see fig 3.3.
80/125 horizontal air/flue duct, see fig 3.4.
80/125 Vertical air/flue duct and terminal, see fig 3.5.
Flue extensions are available to extend the length, both
90° bends and 45° elbows are also available. Refer to
flue system installation instructions for full details.
When extension pipes are used the flue system must be
designed to have a continuous fall to the boiler of at
least 3° to allow condensate to run out via the drain.
Instructions for installation and servicing ecoTEC plus 0020020828_07
General requirements 3
667
Fig. 3.1
Art. No. 30 39 33
Fig. 3.2 Art. No. 30 39 36
Fig. 3.3 Art. No. 30 39 00
Fig. 3.4 Art. No. 30 32 09
11