Ac Current - UNI-T UT804 Operating Manual

Bench type digital multimeter
Table of Contents

Advertisement

Model UT804: OPERATING MANUAL
D. AC Current (AC+DC measurement is available)
Range
Resolution
400 A
0.01 A
4000 A
0.1 A
40mA
0.001mA
400mA
0.01mA
10A
0.001A
Remarks:
l Display:
a) True rms are valid from 10% of range to 100% of range
b) AC crest factor can be up to 3.0.
c) A residual reading of 80 digits with test leads shorted, will not affect stated accuracy.
d) The accuracy guarantee range 10%-100%.
e) When making AC+DC measurment, the accuray need to add(1%+35 digits)of reading based on the above table.
l At 10A range:
a) When the measured current is
b) When the measured current is between >5A-10A, continuous measurement
than 15 minutes.
Bandwidth
Accuracy
45Hz~1kHz
(0.7%+15)
>1kHz~5kHz
(1%+30)
>5kHz~10kHz
(2%+40)
45Hz~1kHz
(1.5%+40)
>1kHz~ 5kHz
(2.5%+40)
>5kHz~10kHz
(5%+40)
5A, continuous measurement is allowed.
Overload Protection
0.5A, 250V, fast type fuse, ø5×20mm
10A, 250V, fast type fuse, ø5×20mm
10 seconds and interval more
61