Measuring Frequency / Duty Cycle; Frequency / Duty Cycle Measurement - UNI-T UT804 Operating Manual

Bench type digital multimeter
Table of Contents

Advertisement

I. Measuring Frequency / Duty Cycle
Figure 3-14. Frequency / Duty Cycle Measurement
Warning
To avoid harms to you, please do not attempt to
input tested frequency voltage higher than 30V rms.
42
Model UT804: OPERATING MANUAL
To measure frequency and duty cycle, connect the
Meter as Figure 3-14 and do the following:
1. Insert the red test lead into the Hz terminal and the
black test lead into the COM terminal.
Hz %
2. Set the rotary switch to
mV
button to select the Hz measurement mode for
frequency measurement or % for duty cycle
measurement.
The SELECT button cycles among
and duty cycle.
3. Connect the test leads across with the object being
measured.
The measured value shows on the primary display.
Note
l
The requirement of Input amplitude "a" is as follows:
When 10Hz~40MHz: 200 mV
40MHz: Un-specified
l
When Hz or Duty Cycle measurement has been
completed, disconnect the connection between the
testing leads and the circuit under test and remove
the test leads away from the input terminals.
and press SELECT
, frequency
mV
a
30Vrms;