Measurement Operation; Dc Voltage Measurement - UNI-T UT50E Operating Manual

Table of Contents

Advertisement

Measurement Operation(1)

l Make sure the Sleep Mode is not on if you found
there is no display on the LCD after turning on the
Meter.
l Make sure the Low Battery Display
false readings may be provided.
l Pay extra attention to the
besides the input terminals of the Meter before carrying
out measeurement.
A. DC Voltage Measurement
( figure 3)
Warning
To avoid harms to you or damages to the Meter from
electric shock, please do not attempt to measure
voltages higher than 1000V or 750V rms although
readings may be obtained.
The DC Voltage ranges are: 200mV, 2V, 20V, 200V and
1000V. To measure DC voltage, connect the Meter as
follows:
1.
Insert the red test lead into the V
terminal and the black test lead into the COM input
terminal.
2.
Set the rotary switch to an appropriate measurement
position in V
3.
Connect the test leads across with the object being
measured.
The measured value shows on the display.
Model UT50E: OPERATING MANUAL
symbol which is located
(see figure 3)
red
range.
13
is not on, otherwise
black
o
C input