Temperature / Care Of The Boiler - Baxi Duo-tec 2 Combi GA Range User's Operating Instructions & Important Warranty Information

Gas fired wall mounted condensing combination boiler
Hide thumbs Also See for Duo-tec 2 Combi GA Range:
Table of Contents

Advertisement

Domestic Hot Water
Temperature Adjustment
Temperature Adjustment
Summer - Winter - Only Heating
Mode
The
button can be pressed so that the display shows the following
information:-
1 press - '00' alternates with Sub-Code (only when fault on boiler) or '000'
2 presses - '01' alternates with CH Temperature
3 presses - '02' alternates with Outside Temperature (where Sensor fitted)
4 presses - '03' alternates with DHW Temperature
5 presses - '04' alternates with DHW Temperature
6 presses - '05' alternates with System Water Pressure
7 presses - '06' alternates with Return Temperature
8 presses - '04' alternates with Flue Temperature
9 presses - '05' alternates with Heat Exchanger Temperature
6
© Baxi Heating UK Ltd 2013
Display Screen
Central Heating

3.0 Temperature / Care of the Boiler

3.1
To increase or decrease the boiler temperature
1. Press the (
2. Press the (
NOTE: An NTC device is positioned in the heat exchanger
which shuts down the appliance if the boiler temperature
exceeds 100°C. Press the (
R
normal operating conditions.
3.2
To increase or decrease the domestic hot water
(DHW) temperature
1. Press the (
2. Press the (
3.3
Summer - Winter - Only Heating Mode
R
1. Press (
2. See 3.1 or 3.2 to set the required temperature.
3.4
Cleaning the Outercase
The painted panels should be wiped with a damp cloth and
then dried completely. DO NOT USE ABRASIVE CLEANING
AGENTS.
3.5
Boiler Frost Protection
1. The boiler incorporates an integral frost protection feature
that will operate in both CH & DHW modes, and also when in
standby (
2. If the boiler temperature falls below 5° C, then the boiler will
operate until the water temperature has been raised.
3. Further protection may be required for the system. Consult
your installer for details.
3.6
Information Display
1. The table opposite shows information that can be displayed
by pressing the
) to increase the CH temperature.
) to decrease the CH temperature.
R
) button to re-establish
) to increase the DHW temperature.
) to decrease the DHW temperature.
) button until the required mode appears:-
Summer - DHW only request mode
Winter - DHW & CH request mode
Only Heating - Only CH request mode
displayed).
button.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents