Baxi Platinum 2 Combi 28 GA User's Operating Instructions & Important Warranty Information
Baxi Platinum 2 Combi 28 GA User's Operating Instructions & Important Warranty Information

Baxi Platinum 2 Combi 28 GA User's Operating Instructions & Important Warranty Information

Gas fired wall mounted condensing combination boiler
Hide thumbs Also See for Platinum 2 Combi 28 GA:

Advertisement

i-THINK Set Up Guide,
User's Operating Instructions &
Important Warranty Information
Platinum 2 Combi GA Range
Gas Fired Wall Mounted Condensing
Combination Boiler
Please keep these instructions in a safe place.
If you move house, please hand them over to the next occupier.
© Baxi Heating UK Ltd 2011

Advertisement

Table of Contents
loading

Summary of Contents for Baxi Platinum 2 Combi 28 GA

  • Page 1 Important Warranty Information Platinum 2 Combi GA Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. © Baxi Heating UK Ltd 2011...
  • Page 2: Table Of Contents

    Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk © Baxi Heating UK Ltd 2011 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any...
  • Page 3: Quick Reference Guide

    Outdoor Sensor Connected Text 1 Text 2 System / Appliance Attention Required Text 3 Maintenance / Special Mode Water Pressure too low Display showing all available segments Change Battery (only if radio control fitted) © Baxi Heating UK Ltd 2011...
  • Page 4: Troubleshooting

    While flashing turn CONTACT YOUR the Selector Button to toggle between Yes and No. Select INSTALLER OR If it does Yes and press the Selector not reset SERVICE Button to select. ENGINEER. Selector Button © Baxi Heating UK Ltd 2011...
  • Page 5 Error Code 118 showing low pressure. If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible © Baxi Heating UK Ltd 2011...
  • Page 6: Setting The Time

    Button to the required year. Set time and date Set time and date Year 2008 Year 2009 STEP 11 Press the MENU button twice to return to normal display screen. 03. June 2009 11:30 Wednesday 1.6 bar © Baxi Heating UK Ltd 2011...
  • Page 7: Setting The Central Heating Times

    1’. Press Selector Button to select and the screen goes back Time central heating CH1 Time central heating CH1 Mon - Sun Mon - Sun: 1st Time ON to STEP 6. Set to Time setting 1 06:00 © Baxi Heating UK Ltd 2011...
  • Page 8: Central Heating Mode

    Press the MENU button active until the i-Think controller is set to twice to return to normal the relevant cental heating mode ie. Reduced display screen. or Timed - see Section 5.1 Selecting the Central Heating Mode. © Baxi Heating UK Ltd 2011...
  • Page 9: Mode Selection/Temp Adjustment

    This setpoint change will remain active until the next programmed On period when the setpoint will revert to the permanent comfort setpoint. © Baxi Heating UK Ltd 2011...
  • Page 10 Selector Button to select. twice to return to normal Temperature setting is now display screen. complete. Temps / mode hot water 03. June 2009 11:30 Hot water temp setpoint 50 °C Wednesday 1.6 bar © Baxi Heating UK Ltd 2011...
  • Page 11 STEP 1 - Turn the Selector STEP 2 - Press the Selector Button and the temperature Button to select. will appear. Turn the Button again and whilst flashing keep turning the dial to display the required temperature. © Baxi Heating UK Ltd 2011...
  • Page 12 Button. The Off or Reduced starts described above, and press and scroll from ‘On’ to ‘Off’. flashing, turn the Button to required Confirm by pressing the Selector Button. mode. Press the Button to select. © Baxi Heating UK Ltd 2011...
  • Page 13: Resetting The Boiler

    Error 266:Fan Fault 2. Please contact your Installer, Annual Service Provider or ‘heateam’ - The Service Division of Baxi to arrange your Annual Service. You can contact ‘heateam’ on telephone number 08448 711 545 or visit www.heateam.co.uk © Baxi Heating UK Ltd 2011...
  • Page 14: Repressurising System

    Keep the pipe in a safe place for future use. Fig. 1 04. November 2008 08:50 Normal Pressure Tuesday 1.6 bar System Pressure Fig. 2 Requires Repressurising © Baxi Heating UK Ltd 2011...
  • Page 15: Clearances

    Your installer should have insulated any exposed pipework. 355mm* In Operation *345 when i-THINK Fig. 4 controller removed © Baxi Heating UK Ltd 2011...
  • Page 16: Legislation

    The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service. 4. The completed Benchmark Checklist may be required in the event of any warranty work. © Baxi Heating UK Ltd 2011...
  • Page 17: Care Of The Boiler

    90° ( turn) downwards 2. You can contact ‘heateam’ on telephone number 08448 711 545 or visit www.heateam.co.uk as soon as possible. Yellow Tap - Gas Black Taps - Water © Baxi Heating UK Ltd 2011...
  • Page 18: Fault Finding

    110, 125, 133, 128 & 384 are displayed it is possible to Selector Button to select. relight the boiler. 4. If this does not have any effect, or the codes are displayed regularly further investigation is required. © Baxi Heating UK Ltd 2011...
  • Page 19: Notes

    12.0 Notes © Baxi Heating UK Ltd 2011...
  • Page 20: Warranty & Service

    5 Years Free Warranty - register today To receive your 5 years free warranty please complete the form supplied with the boiler or simply call heateam, the service of Baxi Heating UK Limited on 0844 871 1525. Our promise to you...

This manual is also suitable for:

Platinum 2 combi 40 gaPlatinum 2 combi 33 ga

Table of Contents