REFR I G ER AN T SY S TE M D IA GR A M
Muffler
Pressure
switch
Compressor
Sub-accumulator
Refrigerant direction
Refrigerant pipe diameter
Liquid : 3/8" (9.52 mm)
Gas : 5/8" (15.88 mm)
2008.01.09
Heat exchanger
3-Way valve
(Large)
4-Way valve
4
(indoor unit)
3-Way valve (Small)
Heat exchanger
(outdoor unit)
Strainer
Expansion
valve
Strainer