AXIS 210A/211A - Troubleshooting
66
Symptoms, Possible Causes and Remedial Actions
Problems setting the IP address
When using ARP/Ping.
The camera is located on a different
subnet.
The IP address is being used by another
device
Possible IP address conflict with
another device on the same subnet.
The camera cannot be accessed from a browser
The IP address has been changed by
DHCP.
Proxy server.
Other networking problems.
Cannot log in.
Incorrect host name.
Cannot send notifications, uploads, alarms, etc, to a destination outside the local network
Firewall protection.
Camera is accessible locally, but not externally
Firewall protection.
Default routers required.
Poor or intermittent network connection.
Network switch.
Try the installation again. The IP address must be set within two minutes after power has
been applied to the camera. Ensure the Ping length is set to 408. See the Installation
Guide.
If the IP address intended for the camera and the IP address of your computer are located
on different subnets, you will not be able to set the IP address. Contact your network
administrator to obtain an appropriate IP address.
Disconnect the camera from the network. Run the Ping command. (In a Command/DOS
window, type ping and the IP address of the unit).
If you receive: Reply from <IP address>: bytes = 32; time = 10 ms..... - this means that
the IP address may already be in use by another device on your network. You must obtain
a new IP address and reinstall the unit.
If you see: Request timed out - this means that the IP address is available for use with
your camera. In this case, check all cabling and reinstall the unit.
The static IP address in the camera is used before the DHCP server sets a a dynamic
address. This means that if the same default static IP address is also used by another
device, there may be problems accessing the camera. To avoid this, set the static IP
address to 0.0.0.0.
1) Move the camera to an isolated network or to one with no DHCP or BOOTP server. Set
the IP address again, using the AXIS IP Utility (see the Installation Guide) or the ARP/Ping
commands.
2) Access the unit and disable DHCP in the TCP/IP settings. Return the unit to the main
network. The unit now has a fixed IP address that will not change.
3) As an alternative to 2), if dynamic IP address via DHCP or BOOTP is required, select the
required service and then configure IP address change notification from the network set-
tings. Return the unit to the main network. The unit now has a dynamic IP address, but
will notify you if the address changes.
If using a proxy server, try disabling the proxy setting in your browser.
Test the network cable and connectors by connecting it to another network device, then
Ping that device from your workstation. See the instructions above.
When HTTPS is enabled, ensure that the correct protocol (HTTP or HTTPS) is used when
attempting to log in. You may need to manually type in http or https in the browser's
address bar.
Check that the host name and DNS server settings are correct. See the basic and
advanced TCP/IP settings.
The camera can be configured to use a SOCKS server to reach networks on the other side
of a firewall/proxy server.
Check the Internet firewall with your system administrator.
Check if you need to configure the default router settings.
If using a network switch, check that the port on that device uses the same setting for
the network connection type (speed/duplex) as set in the advanced TCP/IP settings.
The Auto-Negotiate setting is recommended.