AXIS 207W/AXIS 207MW - System Options
35
FTP
The FTP server running in the AXIS 207W/AXIS 207MW enables the upload of e.g. new
firmware, user applications, etc. Check the box to enable the service.
RTSP
The RTSP protocol allows a connecting client to start an MPEG-4 stream. Check the box to
enable the RTSP server and enter the RTSP port number to use. The default setting is 554.
Note that MPEG-4 streams will not be available if this is not enabled.
Network Traffic
Connection Type - The default setting is Auto-negotiate, which means that the correct
speed is automatically selected. If necessary, you can set the connection speed by selecting
it from the drop-down list.
Maximum bandwidth - To minimize the impact on other services running on your
network, it is possible to configure the maximum network bandwidth the product will be
allowed to use. Specify the maximum bandwidth (in Mbit/s or kbit/s) allowed, or set to
Unlimited.
For more information, please see the online help
.
Wireless
These settings should always be made first in the camera and in the wireless access point
second. This ensures that the camera is always accessible when making changes.
Using a wired connection and/or HTTPS ensures greater secrecy while making these
settings.