Preparation For Storage - ATN ODIN Operator's Manual

Thermal multi-purpose system
Table of Contents

Advertisement

(3) Mount the monocular with adapter onto the M16/M4 receiver rail
per paragraph 2.1.8., steps 3 and 4.
(4) Rotate the diopter adjustment for the clearest view of the image
intensifier screen.
(5) The objective lens is set at infinity focus. The objective lens
houses the Variable Pivot Technology module. The VPT allows the
user to rotate the screen to match the angle of the Odin. To do this
grab the front lens objective and rotate either clockwise or coun-
terclockwise to the image is at desired location. You can also elec-
tronically rotate the icon position in your scope. Select the rotate
icon and then adjust through the menu buttons.
(6) Select the reticle icon in the view screen.
(7) Adjust the windage and elevation through the selected icons in
view screen.

3.2.7. PREPARATION FOR STORAGE

(1) Shutdown. Perform the following procedures to shut down the
monocular.
(a) Turn the monocular power switch to the OFF position.
(b) Remove the monocular from the headmount, helmet mount
or weapon and remove the weapon mount from the monocular.
WARNING
Do not carry batteries in pockets containing metal objects
such as coins, keys, etc. Metal objects can cause the batteries
to short circuit and become very hot.
(2) Packaging After Use.
(a) Remove battery cap and remove battery.
(b) Inspect the battery housing for corrosion or moisture. Clean
and dry if necessary.
(c) Replace the battery cap.
(d) Remove the demist shield or sacrificial window if installed.
Install objective lens cap.
NOTE
• Prior to placing Odin into carrying case, ensure Odin and
3-16