NOTE: Log-set fits tightly into firebox. Some force
may be necessary to remove.
7.
Unplug the log set LED wire harness from unit.
8.
Loosen the screws on the 2 partially reflective glass
retaining clips: bottom left side and bottom right side
of the rear partially reflective glass panel and turn the
clips downward.
9.
Carefully lift the partially reflective glass out of the
fireplace and set aside in a safe location.
10.
Remove the 2 screws located on the left and right
of the 3-light LED strip/panel below the rear partially
reflective glass.
11.
Remove the wire nut connections at the end of the light
harness wires, just in front of the LED Driver Board.
12.
Snip the plastic wire ties which secure the internal
wires together to free up the light harness wires.
13.
Remove the light strip and harness.
14.
Mount the new replacement component in the original
location,
15.
Properly orient the new LED strip and reconnect all of
the wiring connections.
16.
Reassemble in the reverse order as above.
!
NOTE: See Helpful Hints Section for reassembly.
REPLACEMENT INSTRUCTIONS:
REMOVABLE UNITS

ON/OFF SWITCH REPLACEMENT

Tools Required: Phillips Head Screwdriver
Flat Head Screwdriver
WARNINg: If the fireplace was operating prior to
servicing allow at least 10 minutes for light bulbs and
heating elements to cool off to avoid accidental burning
of skin.
WARNINg: Disconnect power before attempting any
maintenance or cleaning to reduce the risk of electric
shock or damage to persons.
1.
Remove the unit from the wall.
2.
Remove the 9 screws along the left, right and back
edge of the top panel
3.
Carefully lift and reposition the top panel inside the
upper cavity to access the upper components. Use
care to not damage the wires attached to the upper
panel when repositioning.
4.
Depress the retainer clips on 2 sides of the switch and
push the switch out through the front face of the upper
air-intake panel.
5.
Remove the wires attached to the switch noting the
original location and orientation.
!
NOTE: Using a flat head screwdriver gently pry be-
tween the end of the connector and the switch to release
the wires.
6.
Properly orient the new switch and reconnect all of the
wiring connections.
7.
Reassemble in the reverse order as above.
!
NOTE: See Helpful Hints Section for reassembly.

SWITCHBOARD REPLACEMENT

Tools Required: Phillips Head Screwdriver
Flat Head Screwdriver
WARNINg: If the fireplace was operating prior to
servicing allow at least 10 minutes for light bulbs and
heating elements to cool off to avoid accidental burning
of skin.
WARNINg: Disconnect power before attempting any
maintenance or cleaning to reduce the risk of electric
shock or damage to persons.
1.
Remove the unit from the wall.
2.
Remove the 9 screws along the left, right and back
edge of the top panel
3.
Carefully lift and reposition the top panel inside the
upper cavity to access the upper components. Use
care to not damage the wires attached to the upper
panel when repositioning.
4.
Slightly depress the tips of the Switchboard mounting
tabs with needle nose pliers, just enough to allow you
to pull the old board off.
5.
Remove the plug attached to the switchboard noting
the original orientation.
6.
Properly orient the new board and reconnect the wiring
connections.
7.
Reassemble in the reverse order as above.
!
NOTE: See Helpful Hints Section for reassembly.
VOLTAgE SELECTOR SWITCH REPLACE-
MENT
Tools Required: Phillips Head Screwdriver
Flat Head Screwdriver
WARNINg: If the fireplace was operating prior to
servicing allow at least 10 minutes for light bulbs and
heating elements to cool off to avoid accidental burning
of skin.
WARNINg: Disconnect power before attempting any
maintenance or cleaning to reduce the risk of electric
shock or damage to persons.
1.
Remove the unit from the wall.
2.
Remove the 9 screws along the left, right and back
edge of the top panel
3.
Carefully lift and reposition the top panel inside the
upper cavity to access the upper components. Use
care to not damage the wires attached to the upper
panel when repositioning.
4.
Release the voltage selector switch, mounting bracket
by removing the 2 screws on the upper right hand
side, from the front of the exhaust panel. (The switch
is recessed and the numbers 115 or 230 will be visible
13